unvented system.
I have to change a friends kitchen sink and taps which looks manageable
enough but I note that the water/heating is an unvented cylinder with expansion and pressure safety devices aplenty. I know the system delivers hot water at cold mains pressure but how do I shut off the hot supply so I can disconnect the tap(s). Does turning off the Cold main isolate the hot supply as in combi boiler? Thanks |
#2
Posted to uk.d-i-y
|
|||
|
|||
unvented system.
"wounded horse" wrote in message ... I have to change a friends kitchen sink and taps which looks manageable enough but I note that the water/heating is an unvented cylinder with expansion and pressure safety devices aplenty. I know the system delivers hot water at cold mains pressure but how do I shut off the hot supply so I can disconnect the tap(s). Does turning off the Cold main isolate the hot supply as in combi boiler? yes but you may find the stored pressure takes some time to run down |
#3
Posted to uk.d-i-y
|
|||
|
|||
unvented system.
In an earlier contribution to this discussion,
John wrote: "wounded horse" wrote in message ... I have to change a friends kitchen sink and taps which looks manageable enough but I note that the water/heating is an unvented cylinder with expansion and pressure safety devices aplenty. I know the system delivers hot water at cold mains pressure but how do I shut off the hot supply so I can disconnect the tap(s). Does turning off the Cold main isolate the hot supply as in combi boiler? yes but you may find the stored pressure takes some time to run down And you may have to re-establish the air bubble when you've finished - for which there should be some instructions on the hot cylinder. If you're *very* lucky, there may be isolator valves on the pipework under the sink. If you can turn these off, and just disconnect the pipework on the tap side of the valves, you won't have to worry about the pressurised system. -- Cheers, Set Square ______ Please reply to newsgroup. Reply address is invalid. |
#4
Posted to uk.d-i-y
|
|||
|
|||
unvented system.
Vot is re-establish air bubble pliz. There are no isolators under the sink.
so I need to know this before I decide to pass on this job. Thanks |
#5
Posted to uk.d-i-y
|
|||
|
|||
unvented system.
In an earlier contribution to this discussion,
wounded horse wrote: Vot is re-establish air bubble pliz. There are no isolators under the sink. so I need to know this before I decide to pass on this job. Thanks I am by no means an expert on these things. But, AIUI, an unvented hot cylinder has to have some trapped air above the water, to allow for expansion when the water is heated - otherwise it would burst. These things are sufficiently dangerous, anyway, that you need appropriate qualifications to install them - it's not a DIY job. But I believe that there *is* a user procedure for re-establishing the air pocket when necessary - typically when the pressure release safety valve has operated. A friend of mine has got one, and there are some instructions attached to the cylinder, detailing how to do this. -- Cheers, Set Square ______ Please reply to newsgroup. Reply address is invalid. |
#6
Posted to uk.d-i-y
|
|||
|
|||
unvented system.
I am by no means an expert on these things. But, AIUI, an unvented hot
cylinder has to have some trapped air above the water, to allow for expansion when the water is heated - otherwise it would burst. Note that only some unvented cylinders require this. I believe Heatrae Sadia Megaflo is one. Other designs use conventional pressure vessels. Christian. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Minimum flow rate required for unvented domestic hot water system | UK diy | |||
The End of Pensions -- But Keep Voting for Republicans as You Spend Your Golden Years in a Cardboard Box on the Street | Metalworking | |||
Unvented system and hot water | UK diy | |||
New condensing boiler installation - truth or lies | UK diy | |||
Unvented hot water system | UK diy |