Hope someone can shed some light.....
For no reason today, my hot water and heating failed. The boiler (Potterton Kingfisher) fires up, although the temperature of the flue gases are much higher than normal, and runs for about a minute before shutting down - possibly overheating. The pump is ok (have removed and checked & only 3 months old), and if i push the (2 port Honeywell) motorised valve round with a screwdriver, the pump starts, although there is a sound like water cavitation as if it can't circulate at all. The wiring seems ok, but I am not sure where to go next. I haven't got a lot of money at the moment, so it would be good if someone could guide me as to where to go next. A plumber is the absolute last resort! Thanks Russell |
#2
![]() |
|||
|
|||
![]()
The pump is ok (have removed and checked & only 3 months old),
and if i push the (2 port Honeywell) Before we go any further, bleed all of your radiators and any bleed valves you see elsewhere on the pipework, such as near the pump, boiler and zone valves. The symptoms seem to indicate that no water is flowing. How are you sure the pump is working? Don't be distracted by the fact that the pump is new. The "bathtub" reliability curve indicates that brand new equipment is less reliable than stuff that has been installed and working for a couple of years. Christian. |
#3
![]() |
|||
|
|||
![]() "Russell" wrote in message om... Hope someone can shed some light..... For no reason today, my hot water and heating failed. The boiler (Potterton Kingfisher) fires up, although the temperature of the flue gases are much higher than normal, and runs for about a minute before shutting down - possibly overheating. The pump is ok (have removed and checked & only 3 months old), and if i push the (2 port Honeywell) motorised valve round with a screwdriver, the pump starts, although there is a sound like water cavitation as if it can't circulate at all. The wiring seems ok, but I am not sure where to go next. I haven't got a lot of money at the moment, so it would be good if someone could guide me as to where to go next. A plumber is the absolute last resort! Thanks Russell Does the system have a header tank? (i.e not a combi boiler or sealed system) If so the symptoms could mean that your header tank is empty and so there is not enough water in your system to allow the pump to drive it. This can happen when the ball valve sticks closed and the water slowly evapourates. HTH Dave R |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
central heating pipework | UK diy | |||
FAQ Question re. central heating | UK diy | |||
2 port Vs 3 port central heating valves | UK diy | |||
Further to my last post entitled 'Flushing and treating central heating question' | UK diy | |||
Costs for Gas Central heating from Electric storage | UK diy |