Hi I have recently moved into a new house (to me anyway) and am going to be
doing some improvements. One of which is to insulate the attic as the present insulation material is woefully inadequate. I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. Also the house is a upstairs downstairs type and I have discovered that there is no insulation of any type between the floors. Just a gap. Should I put any insulation in there? It would have to be a type that could be put in without lifting the flooring but there is some access from a cupboard under the stairs. Would it be worth while or would the hassle involved outweigh the advantages? Or is this not normally insulated? I hope that I can get some correct advice from this group as the person who is giving me advice at the moment seems to make it up as he goes along. I think he may be for the chop. Thanks Karen |
#2
|
|||
|
|||
Karen wrote:
I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. While it's technically correct, the amount of energy it will reflect will be negligible, so for all intents and purposes they are talking ********. Also the house is a upstairs downstairs type and I have discovered that there is no insulation of any type between the floors. Just a gap. Should I put any insulation in there? It would have to be a type that could be put in without lifting the flooring but there is some access from a cupboard under the stairs. Would it be worth while or would the hassle involved outweigh the advantages? Or is this not normally insulated? Why would you insulate the floor? Any heat lost from downstairs will simply end up upstairs - so overall you lose nothing. I hope that I can get some correct advice from this group as the person who is giving me advice at the moment seems to make it up as he goes along. I think he may be for the chop. Good plan. His name isn't IMM/Drivel, is it? -- Grunff |
#3
|
|||
|
|||
"Grunff" wrote in message ... Karen wrote: I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. While it's technically correct, the amount of energy it will reflect will be negligible, so for all intents and purposes they are talking ********. But, the foil will act as a vapour barrier, all be it an imperfect one, which is a worthwhile reason to do it. -- 73 Brian, G8OSN www.g8osn.org.uk |
#4
|
|||
|
|||
On Wed, 05 Oct 2005 16:17:42 GMT, "Brian Reay"
wrote: "Grunff" wrote in message .. . Karen wrote: I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. While it's technically correct, the amount of energy it will reflect will be negligible, so for all intents and purposes they are talking ********. But, the foil will act as a vapour barrier, all be it an imperfect one, which is a worthwhile reason to do it. Where is the 'vapour' coming from Brian? I would have *thought* you wouldn't want to trap vapour in the room but let it permeate out through the walls / ceilings etc and if there was a vapour trap above the ceiling it would keep the plasterboard damp? All the best .. T i m |
#5
|
|||
|
|||
T i m wrote:
snip Where is the 'vapour' coming from Brian? I would have *thought* you wouldn't want to trap vapour in the room but let it permeate out through the walls / ceilings etc and if there was a vapour trap above the ceiling it would keep the plasterboard damp? Nope. Plasterboard isn't an insulator. It'll be at essentially the same temperature as the room. However, it's essentially porous to water vapour, and what that means is that you get warm damp air on the far side of the insulation, shortly after you start breathing or cooking in a room. It then permeates through insulation, cooling as it goes. If you are unlucky, it cools to below the dew-point, and you get condensation in the insulation, which can cause whatever's touching it to rot rapidly. The right way to insulate nearly all structures is to have the inside a vapour-tight box, with air entry and exit done through ventilators, not a porous structure. Otherwise, if you try to insulate highly, you're likely to get condensation where you don't want it. |
#6
|
|||
|
|||
On 05 Oct 2005 16:52:36 GMT, Ian Stirling
wrote: T i m wrote: snip Where is the 'vapour' coming from Brian? I would have *thought* you wouldn't want to trap vapour in the room but let it permeate out through the walls / ceilings etc and if there was a vapour trap above the ceiling it would keep the plasterboard damp? Nope. Plasterboard isn't an insulator. It'll be at essentially the same temperature as the room. Ok .. However, it's essentially porous to water vapour, and what that means is that you get warm damp air on the far side of the insulation, shortly after you start breathing or cooking in a room. That's what I thought ... It then permeates through insulation, cooling as it goes. If you are unlucky, it cools to below the dew-point, and you get condensation in the insulation, which can cause whatever's touching it to rot rapidly. Ah .. not a good thing then. The right way to insulate nearly all structures is to have the inside a vapour-tight box, with air entry and exit done through ventilators, not a porous structure. Understood, so anything non permeable 'above' the ceiling plasterboard and between the joists could cause moisture to collect and via capilary action wet the roof timbers? Even of it didn't get *through* the plasterboard to 'cool to the dew point' where would it go? Otherwise, if you try to insulate highly, you're likely to get condensation where you don't want it. And that's what I thought ... something to be said for draughty sash windows then ;-) All the best T i m |
#7
|
|||
|
|||
In article ,
"Brian Reay" writes: But, the foil will act as a vapour barrier, all be it an imperfect one, which is a worthwhile reason to do it. It's not. The permiability of the plasterboard is very much lower than the rate moisture escapes from even a poorly ventilated loft. If the amount of moisture in the loft is an issue, then you need to ventilate the loft, and it's much more likely to be comming from a roof leak or header tanks, or holes punched in the ceiling for recessed lamps, loft hatches, etc. Forget about the tin foil. -- Andrew Gabriel |
#8
|
|||
|
|||
"Andrew Gabriel" andrew@a17 wrote in message .. . In article , "Brian Reay" writes: But, the foil will act as a vapour barrier, all be it an imperfect one, which is a worthwhile reason to do it. It's not. The permiability of the plasterboard is very much lower than the rate moisture escapes from even a poorly ventilated loft. So why do building regs now specify foil backed plasterboard? -- 73 Brian, G8OSN www.g8osn.org.uk |
#9
|
|||
|
|||
On Wed, 05 Oct 2005 20:59:54 +0000, Brian Reay wrote:
"Andrew Gabriel" andrew@a17 wrote in message .. . In article , "Brian Reay" writes: But, the foil will act as a vapour barrier, all be it an imperfect one, which is a worthwhile reason to do it. It's not. The permiability of the plasterboard is very much lower than the rate moisture escapes from even a poorly ventilated loft. So why do building regs now specify foil backed plasterboard? There are plenty of regs which have only a marginal impact of the quality of the end result, but make significant cost implications for compliance. This problem is not confined to the BRs. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#10
|
|||
|
|||
In article , Grunff
writes Karen wrote: I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. While it's technically correct, the amount of energy it will reflect will be negligible, so for all intents and purposes they are talking ********. Gggggrn not the right answer, foil will only reflect heat where the transfer mechanism is radiation, when in direct contact with any material, the heat transfer mech will be conduction so it wont help at all. It'll only help it's adjacent to an air gap and even then the efficiency will be reduced as the foil tarnishes. I agree with the end result tho', ******** was spake . . . -- fred |
#11
|
|||
|
|||
fred wrote:
Gggggrn not the right answer, foil will only reflect heat where the transfer mechanism is radiation, when in direct contact with any material, the heat transfer mech will be conduction so it wont help at all. I was taking that into account, which is why I said negligibl (honest!). The foil won't be in direct contact with the plasterboard right across - there will be a proportion of the area, maybe 10% or more, where the foil is sitting there with a gap between it and the pb. In tose areas, the heat transfer between the pb and the foil will be convective and radiative. :-P -- Grunff |
#12
|
|||
|
|||
In article , Grunff
writes fred wrote: Gggggrn not the right answer, foil will only reflect heat where the transfer mechanism is radiation, when in direct contact with any material, the heat transfer mech will be conduction so it wont help at all. I was taking that into account, which is why I said negligibl (honest!). The foil won't be in direct contact with the plasterboard right across - there will be a proportion of the area, maybe 10% or more, where the foil is sitting there with a gap between it and the pb. In tose areas, the heat transfer between the pb and the foil will be convective and radiative. :-P Yeah right, was just bringing you back down to earth after my unbridled praise in the solder thread :-). -- fred |
#13
|
|||
|
|||
On Wed, 05 Oct 2005 19:50:31 GMT, fred wrote:
foil will only reflect heat where the transfer mechanism is radiation, when in direct contact with any material, the heat transfer mech will be conduction so it wont help at all. Like the guy in the camping shop that said 'put some of that foil they use for emergency blankets on top of your airbed and under your sleeping bag to keep you warm ..." shakes head All the best .. T i m |
#14
|
|||
|
|||
"Karen" wrote I was told that before I lay the new insulation I should put down a layer of aluminium foil before laying the insulation between the joists, as this will reflect heat back down into the rooms below. Is this correct or his the person giving me this advice talking a load of ********. I hope that I can get some correct advice from this group as the person who is giving me advice at the moment seems to make it up as he goes along. I think he may be for the chop. Did this person also advise you to wrap the tinfoil around your head to stop aliens reading your mind? If so definitely give him the chop. Also run away quite quickly......... hth Neil |
#15
|
|||
|
|||
Gripper wrote:
Did this person also advise you to wrap the tinfoil around your head to stop aliens reading your mind? If so definitely give him the chop. Also run away quite quickly......... What if he advised earth bonding the foil? -- http://gymratz.co.uk - Best Gym Equipment & Bodybuilding Supplements UK. http://trade-price-supplements.co.uk - TRADE PRICED SUPPLEMENTS for ALL! http://fitness-equipment-uk.com - UK's No.1 Fitness Equipment Suppliers. http://gymratz.co.uk/hot-seat.htm - Live web-cam! (sometimes) |
#16
|
|||
|
|||
""Pet @ www.gymratz.co.uk ;¬)"" wrote Gripper wrote: Did this person also advise you to wrap the tinfoil around your head to stop aliens reading your mind? If so definitely give him the chop. Also run away quite quickly......... What if he advised earth bonding the foil? then he is a "Competent Person" with regards to Part P of the regs: not only must the OP follow his advice to the letter, she must pay him great wodges of cash, and not run away at all. :- |