Greetings all
I've had some doors rehung indoors and need to move the light switches as they are now hidden when the door opens. I have access to the cabling in the loft but is this something that a DIYer can do or do the new regulations require an electrician? Thanks for your help Sam |
#2
![]() |
|||
|
|||
![]()
sam wrote:
I've had some doors rehung indoors and need to move the light switches as they are now hidden when the door opens. I have access to the cabling in the loft but is this something that a DIYer can do or do the new regulations require an electrician? You can do that since it does not fall under the new regulations (i.e. it is a "minor work"). The exception would be if the switch were in a bathroom or kitchen. -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#3
![]() |
|||
|
|||
![]()
John Rumm wrote:
You can do that since it does not fall under the new regulations (i.e. it is a "minor work"). The exception would be if the switch were in a bathroom or kitchen. Hi John So what jobs are OK and which aren't? I though that if it involved a new cable it was banned by the Part P Gestapo. So changing a switch/socket for a new one was OK. but as the OP want's to move the switches to the other side of the door opening it must involve a new cable? Dave |
#4
![]() |
|||
|
|||
![]()
david lang wrote:
So what jobs are OK and which aren't? I though that if it involved a new cable it was banned by the Part P Gestapo. So changing a switch/socket for a new one was OK. but as the OP want's to move the switches to the other side of the door opening it must involve a new cable? AIUI the following are OK: 1 Changing accessories 2 Adding a spur to existing circuit power circuit 3 Adding socket to existing ring 4 Replacing a cable section in an existing circuit 5 Adding a lighting point or switch 6 Any amount of life threatening bodgery with "appliances", extension leads, multiway adaptors 7 Changing a CU fuse, resetting MCB etc. Things verboten under possible penalty of being shoved up the orifice of the deputy prime minister include: 8 Adding a complete new circuit (even if it is the better/safer alternative to copious application of 2 and 3 above) 9 Work in restricted locations[1] (i.e. bathroom and kitchen [2]) 10 Work that messes with the CU, Meter, Tails etc (although again open to discussion if you want to do 4 above on the first/last section of a circuit). 11 Upgrading earth bonding to modern standards - not because it is in itself dangerous, but because it would normally required some of 9 above. [1] Some debate as to if changing an accessory like for like is allowed [2] Work in a bedroom with on-suite facilities may or may not be covered depending on the wind direction So all in all a bit of a dogs breakfast! -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |