central heating pipework
I am installing an oil fired central heating and hot water system.
I plan to use 22mm copper pipe as the main primary feed and return, with 15mm pipe as the radiator supply and return. Should I run the 22mm pipe as close as possible to all radiators? Am I best avoiding long runs in 15mm pipe? Can anyone direct me to good in depth guides on central heating installation and plumbing? Anything I have found so far is either very basic or generalised.So any info on the installation for a semi detached house with 11 radiators and 1 hot water tank would be greatly appreciated. |
#2
|
|||
|
|||
central heating pipework
"Robert Frame" wrote in message om... I am installing an oil fired central heating and hot water system. I plan to use 22mm copper pipe as the main primary feed and return, with 15mm pipe as the radiator supply and return. Should I run the 22mm pipe as close as possible to all radiators? Am I best avoiding long runs in 15mm pipe? Can anyone direct me to good in depth guides on central heating installation and plumbing? Anything I have found so far is either very basic or generalised.So any info on the installation for a semi detached house with 11 radiators and 1 hot water tank would be greatly appreciated. see current thread: Heat capacity of central heating pipes That will be fine for starters --- -- Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.507 / Virus Database: 304 - Release Date: 05/08/2003 |
#3
|
|||
|
|||
central heating pipework
In article ,
Robert Frame wrote: I am installing an oil fired central heating and hot water system. I plan to use 22mm copper pipe as the main primary feed and return, with 15mm pipe as the radiator supply and return. Should I run the 22mm pipe as close as possible to all radiators? Am I best avoiding long runs in 15mm pipe? Can anyone direct me to good in depth guides on central heating installation and plumbing? Anything I have found so far is either very basic or generalised.So any info on the installation for a semi detached house with 11 radiators and 1 hot water tank would be greatly appreciated. 1. the myson.co.uk provides a downloadable program for sizing rads and brequired boiler ouputs. You calculate heat loss from the rooms by inserting sizes of walls, windows, materials etc. 2. my local library has a good section on plumbing and house building books 3. the above books tell yuo waht size pipes to use. Small 15 mm pipes can only serve rads outputs of around 6kW, 22m can serve 12kW? (get exact figures from books, or web sites/DIY faq). 4 My oil boiler, located at one of of my end terrace, has 28 mm to a T-pice next to the boiler. From this T-piece; a) 22 mm runs to the upstairs and then goes to 15mm when it enters the floor void (for 3 beds plus one landing rad), b) 22 mm runs through the kitchen (and kitchen rad) to the dining room rad and then changes to 15 mm for the hall and lounge. There is also a T-piece in the 22 mm near the boiler for a 15 mm run to the bathroom, at the back of the kitchen. This may give you some idea. Neil I'll be selling my oil boiler and tank soon? |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
FAQ Question re. central heating | UK diy | |||
2 port Vs 3 port central heating valves | UK diy | |||
Further to my last post entitled 'Flushing and treating central heating question' | UK diy | |||
Dataterm IHC vs Danfoss TP75 Central Heating controllers | UK diy | |||
Costs for Gas Central heating from Electric storage | UK diy |