  #1   Report Post  
Martin
 
Posts: n/a
Default Air Conditioning unit advice wanted


One question,
How do portable units expel the heat?
Most units I have used in the past either have a heat exchanger (and fan)
mounted outside, or require a vent pipe for warm air to be blown out, so how
does a portable unit which says keep doors and windows closed expel the
heat?

"Al" wrote in message
m...
I can't take the heat any more!

Looking at a mobile/cheap air con unit.

B&Q do a couple (although out of stock at the moment) around £180.

Product

http://www.diy.com/bq/product/produc...5&CATID=190440

Anyone used this before or another similar unit? Any good for cooling
down a 12x12 ft room?

Thanks,

Al



  #2   Report Post  
Dave Gibson
 
Posts: n/a
Default Air Conditioning unit advice wanted


"Martin" wrote in message
...

One question,
How do portable units expel the heat?
Most units I have used in the past either have a heat exchanger (and fan)
mounted outside, or require a vent pipe for warm air to be blown out, so

how
does a portable unit which says keep doors and windows closed expel the
heat?


Latent heat of evaporation of water. Room gets cooler, air gets damper.

You get the same effect if you drape wet socks over a fan.

Dave


  #3   Report Post  
John Rumm
 
Posts: n/a
Default Air Conditioning unit advice wanted

Dave Gibson wrote:

does a portable unit which says keep doors and windows closed expel the
heat?



Latent heat of evaporation of water. Room gets cooler, air gets damper.

You get the same effect if you drape wet socks over a fan.


Errr No ;-)

The portable units have a large flexible vent pipe like a tumble dryer -
you poke this out a window or through a vent as Andrew says below. If
you use a window then you want to open it only enough to accommodate the
end of the vent pipe and then preferably "fill in" the rest of the gap
(use a towel or wrap the curtains round the gap etc - some units even
come with foam batts designed for the purpose)

They will condense lots of water out of the air as well - most have an
internal reservoir that needs emptying from time to time. Some you can
connect a hose to if you can find a way to have the water run down hill
to a suitable exit.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/

  #4   Report Post  
Dave Liquorice
 
Posts: n/a
Default Air Conditioning unit advice wanted

On Sun, 10 Aug 2003 21:23:15 +0100, Dave Gibson wrote:

Latent heat of evaporation of water. Room gets cooler, air gets
damper.


Some cheap "air con" units do use this effect and yes they do produce
a stream of cool air but as you say the humidity rises. After a few
hours your in cool sauna... and your own perspiration can't evaporate
either so it becomes really uncomfortable.

Anyway AFAICT the OP is referring to a proper aircon unit as the
features specifically mentions dehumidfication of the air, some thing
that only happens with a proper chiller unit.

Still need to dump the waste heat somewhere though. Depending on the
window design a board with a suitably sized hole would do, but really
only works on a sliding type window rather than an opening vent.

--
Cheers
Dave. pam is missing e-mail



  #5   Report Post  
Andrew McKay
 
Posts: n/a
Default Air Conditioning unit advice wanted

On Sun, 10 Aug 2003 18:33:08 +0000 (UTC), "Martin"
wrote:

How do portable units expel the heat?
Most units I have used in the past either have a heat exchanger (and fan)
mounted outside, or require a vent pipe for warm air to be blown out, so how
does a portable unit which says keep doors and windows closed expel the
heat?


I've got one roughly the same size as the one linked by the OP.

If you recirculate the air, forget it - it'll add to the heat in the
room. Opening a window and dropping the exhaust pipe out can help, but
it doesn't really help much because more warm air comes in the window.

The only solution is a firking great 4in hole thru the outer skin of
the house, thru which you poke the exhaust pipe.

But a 12x12 room? No chance. I've got 2 PCs in my study, combined they
chuck out about 500w of heat. The mobile aircon just about keeps up,
but only just. If I go sit in the study to admire the slightly lower
temperature it's over the top. And my study is something like 6x9.

Basically these mobile units are a pile of pooh. Don't bother is my
suggestion. I understand from comments made by others that you really
need a dual unit, where the fan is inside and the heat exchanger is
outside (I hope I remembered that right). Expect to pay a grand or
more for something like that.

Andrew

Do you need a handyman service? Check out our
web site at http://www.handymac.co.uk


  #6   Report Post  
Malc
 
Posts: n/a
Default Air Conditioning unit advice wanted


"Al" wrote in message
m...
I can't take the heat any more!

Looking at a mobile/cheap air con unit.

B&Q do a couple (although out of stock at the moment) around £180.

Product

http://www.diy.com/bq/product/produc...5&CATID=190440

Anyone used this before or another similar unit? Any good for cooling
down a 12x12 ft room?

As others have said the water filled ones aren't much cop (although some can
be filled with ice) and the portable proper ones don't have much power. A
friend of mine has one and it's about 500W or less of cooling. If you think
about how much energy it takes to heat a room up then it needs the same sort
of power to cool it down. And he has problems sealing around the exhaust
pipe (uses towel stuffed around the window).

--
Malc


  #7   Report Post  
John Rumm
 
Posts: n/a
Default Air Conditioning unit advice wanted

Andrew McKay wrote:

But a 12x12 room? No chance. I've got 2 PCs in my study, combined they
chuck out about 500w of heat. The mobile aircon just about keeps up,
but only just. If I go sit in the study to admire the slightly lower
temperature it's over the top. And my study is something like 6x9.


It seems the performance must vary a fair bit depending on the unit....
I have seen powers ranging from 4000 btu/hour to over 14000 for
monoblock units.

I use a 8000 btu/h in my office (approx 12'x10'x7'6"). With only 2 PCs
on, and me in it, the temp is currently 25.6c. The room next door is
currently 32c. It much less humid in here as well.

Basically these mobile units are a pile of pooh. Don't bother is my
suggestion. I understand from comments made by others that you really
need a dual unit, where the fan is inside and the heat exchanger is
outside (I hope I remembered that right). Expect to pay a grand or
more for something like that.


I would go along with the recommendation for a split unit, although I
would not be quiet as disparaging about the monoblocks if you get one
with enough power and can put up with the noise (i.e. probably not ideal
for the bed room!) Expect to pay 350 quid or more for a decent one though.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/

  #8   Report Post  
Stuart
 
Posts: n/a
Default Air Conditioning unit advice wanted


I can't take the heat any more!

Looking at a mobile/cheap air con unit.



Get a split unit, where the compressor sits outside. Don't waste your money
on cheap portables.

I installed one of these a couple of months ago.
http://tinylink.com/?fgrEyo9D6N

Even with todays extream heat, I had to turn the thing down as it was
getting too cold indoors.

Stuart.
  #9   Report Post  
JW
 
Posts: n/a
Default Air Conditioning unit advice wanted

Anyone used this before or another similar unit? Any good for cooling
down a 12x12 ft room?



From experience, 8000btu/hr units are not equal. Some will do the job,
others wont.
I'd have a look on Ebay for a better quality unit.

Oscar



  #10   Report Post  
Andrew Gabriel
 
Posts: n/a
Default Air Conditioning unit advice wanted

In article ,
Andrew McKay writes:
On Sun, 10 Aug 2003 18:33:08 +0000 (UTC), "Martin"
wrote:

How do portable units expel the heat?
Most units I have used in the past either have a heat exchanger (and fan)
mounted outside, or require a vent pipe for warm air to be blown out, so how
does a portable unit which says keep doors and windows closed expel the
heat?


I've got one roughly the same size as the one linked by the OP.

If you recirculate the air, forget it - it'll add to the heat in the
room. Opening a window and dropping the exhaust pipe out can help, but
it doesn't really help much because more warm air comes in the window.

The only solution is a firking great 4in hole thru the outer skin of
the house, thru which you poke the exhaust pipe.


That doesn't help -- the air still has to come back in from outside.
That's why such units are not as good as two part or fitted units.
Someone gave me one, claiming it not to work, which was for exactly
this reason. I doctored it to add a second hose which draws air in
which is passed across the condensor and expelled again -- this one
fortunately had quite separate air intakes for the condensor from
that for the evaporator which enabled me to keep the inside and
outside air paths isolated. That fixed the problem, but I've never
seen one which comes with two hoses for this purpose.

But a 12x12 room? No chance. I've got 2 PCs in my study, combined they
chuck out about 500w of heat. The mobile aircon just about keeps up,
but only just. If I go sit in the study to admire the slightly lower
temperature it's over the top. And my study is something like 6x9.


Mine's in a 10' x 12' room with computer and TV, but they probably
only total about 200W, and having hacked it, it works quite well.

Basically these mobile units are a pile of pooh. Don't bother is my
suggestion. I understand from comments made by others that you really
need a dual unit, where the fan is inside and the heat exchanger is
outside (I hope I remembered that right). Expect to pay a grand or
more for something like that.


Indeed.

--
Andrew Gabriel


  #11   Report Post  
Gin Smith
 
Posts: n/a
Default Air Conditioning unit advice wanted

Andrew McKay wrote in message . ..
On Sun, 10 Aug 2003 18:33:08 +0000 (UTC), "Martin"
wrote:

How do portable units expel the heat?
Most units I have used in the past either have a heat exchanger (and fan)
mounted outside, or require a vent pipe for warm air to be blown out, so how
does a portable unit which says keep doors and windows closed expel the
heat?


I've got one roughly the same size as the one linked by the OP.

If you recirculate the air, forget it - it'll add to the heat in the
room. Opening a window and dropping the exhaust pipe out can help, but
it doesn't really help much because more warm air comes in the window.

The only solution is a firking great 4in hole thru the outer skin of
the house, thru which you poke the exhaust pipe.

But a 12x12 room? No chance. I've got 2 PCs in my study, combined they
chuck out about 500w of heat. The mobile aircon just about keeps up,
but only just. If I go sit in the study to admire the slightly lower
temperature it's over the top. And my study is something like 6x9.

Basically these mobile units are a pile of pooh. Don't bother is my
suggestion. I understand from comments made by others that you really
need a dual unit, where the fan is inside and the heat exchanger is
outside (I hope I remembered that right). Expect to pay a grand or
more for something like that.

Andrew

Do you need a handyman service? Check out our
web site at http://www.handymac.co.uk


I have one of these from comet - i got it last summer, its a 8000 BTU
unit and it drops the temp of my bedroom (4M x 4M) by about 10
degrees. I agree about the vent pipe - you can either use the foam
rubber sheet they supply you with but with hinged windows (as against
sliding windows) you still end up with huge gaps to let in the hot air
and as you the alterntive is a 4" hold through the wall........BUT in
a true diy fashion i built myself a window wedge from scrap wood that
fits in the opening of the window when its about 1/3 open with a hole
for the vent pipe and sealed round the edges with pipe insulation. So
not i just need to open the window to it fullest extend, then shut it
on the wedge and insert the vent pipe - it makes a good seal all round
including top and bottom.......it works great....only problem is it is
a bit on the large size but still it works

gin
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Air conditioning thread Grunff UK diy 68 August 8th 03 08:21 PM
Height between kitchen worktop and wall unit ? Christian McArdle UK diy 1 August 6th 03 07:37 PM
using a shower unit to heat a swimming pool Smithwood456789 UK diy 11 July 25th 03 10:22 AM
fridge freezer brand advice vilm UK diy 4 July 15th 03 05:14 PM
Welding holes in a chaincase - advice wanted [email protected] UK diy 5 July 15th 03 09:25 AM


All times are GMT +1. The time now is 08:07 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"