DIYbanter

DIYbanter (https://www.diybanter.com/)
-   Metalworking (https://www.diybanter.com/metalworking/)
-   -   Wiring various machine health switches (https://www.diybanter.com/metalworking/306542-wiring-various-machine-health-switches.html)

Ignoramus12838 July 15th 10 09:57 PM

Wiring various machine health switches
 
My mill has a few switches, such as low lubricating oil level and
motor overheat switches, all NC.

I wanted to ask what is the standard way of wiring this stuff. Just
all in big series with E-stop switches? Or separately as separate
inputs so that I would know what the problem is?

i

Karl Townsend July 15th 10 10:28 PM

Wiring various machine health switches
 

"Ignoramus12838" wrote in message
...
My mill has a few switches, such as low lubricating oil level and
motor overheat switches, all NC.

I wanted to ask what is the standard way of wiring this stuff. Just
all in big series with E-stop switches? Or separately as separate
inputs so that I would know what the problem is?

i


If you're short on inputs, just put them on indicator lights. Otherwise, its
a control input. Then you can program what you want. For example, I have low
air do a feedhold then spindle stop. That way you don't ruin a part. You can
just do cycle start when problem is corrected.

Karl




Gunner Asch[_6_] July 15th 10 10:59 PM

Wiring various machine health switches
 
On Thu, 15 Jul 2010 15:57:02 -0500, Ignoramus12838
wrote:

My mill has a few switches, such as low lubricating oil level and
motor overheat switches, all NC.

I wanted to ask what is the standard way of wiring this stuff. Just
all in big series with E-stop switches? Or separately as separate
inputs so that I would know what the problem is?

i


As a machine tool service tech..Id personally love to see some sort of
individual indication of problems, issues and so forth.

If you are up to doing so..it makes life much easier down the road.


Gunner

One could not be a successful Leftwinger without realizing that,
in contrast to the popular conception supported by newspapers
and mothers of Leftwingers, a goodly number of Leftwingers are
not only narrow-minded and dull, but also just stupid.
Gunner Asch

Lloyd E. Sponenburgh[_3_] July 15th 10 11:04 PM

Wiring various machine health switches
 
Ignoramus12838 fired this volley in
:

I wanted to ask what is the standard way of wiring this stuff. Just
all in big series with E-stop switches? Or separately as separate
inputs so that I would know what the problem is?

i


Ig, that's really a matter of choice. I, personally, would want more
information that simply, "something's wrong", but I've wired process
machinery up like that when I didn't have enough inputs on a PLC to
handle all the errors I might have to detect.

When you do it that way, you need to create a step-chart to remind you of
all the things to check when the alarm goes off. Three years from now,
while you're milling parts, it might not be as fresh in your memory as
now.


LLoyd

Martin H. Eastburn July 17th 10 04:24 AM

Wiring various machine health switches
 
I can see digital logic in the use of the switches.

Run if this light is on but when this other lights - shut down....

I'd consider a machine motor off and a all off.

The idea is to have a scram button that is 'all off'. Then Gunner
walks up to troubleshoot and he turns off the motor switches and
enables power. The lights will show. The 'lights' might be relays
that drive lights or fans or pumps...

Martin

Martin H. Eastburn
@ home at Lions' Lair with our computer lionslair at consolidated dot net
"Our Republic and the Press will Rise or Fall Together": Joseph Pulitzer
TSRA: Endowed; NRA LOH & Patron Member, Golden Eagle, Patriot's Medal.
NRA Second Amendment Task Force Originator & Charter Founder
IHMSA and NRA Metallic Silhouette maker & member. http://lufkinced.com/

On 7/15/2010 3:57 PM, Ignoramus12838 wrote:
My mill has a few switches, such as low lubricating oil level and
motor overheat switches, all NC.

I wanted to ask what is the standard way of wiring this stuff. Just
all in big series with E-stop switches? Or separately as separate
inputs so that I would know what the problem is?

i



All times are GMT +1. The time now is 10:31 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.