Pressure washer update (was motor rewinding cost)
Bruce, that's exactly what I think, they wired START in parallel and STOP in series. So all I need is connect the remote STOP wires together. I will try it, hopefully tonight. i |
#2
Posted to rec.crafts.metalworking
|
|||
|
|||
Pressure washer update (was motor rewinding cost)
On Tue, 14 Jul 2009 11:52:38 -0500, Ignoramus13927
wrote: Bruce, that's exactly what I think, they wired START in parallel and STOP in series. So all I need is connect the remote STOP wires together. I will try it, hopefully tonight. i Get the added wires all the way out of there, so you can see what you are doing with only factory wiring. The 20-second time-out could be from the Burner circuit - if the burner doesn't light there will be a time out so you don't get a gas explosion. Should just turn off the gas, but killing the main contactor could be an unintended consequence of how they wired it. -- Bruce -- |
#3
Posted to rec.crafts.metalworking
|
|||
|
|||
Pressure washer update (was motor rewinding cost)
On 2009-07-14, Bruce L Bergman wrote:
On Tue, 14 Jul 2009 11:52:38 -0500, Ignoramus13927 wrote: Bruce, that's exactly what I think, they wired START in parallel and STOP in series. So all I need is connect the remote STOP wires together. I will try it, hopefully tonight. i Get the added wires all the way out of there, so you can see what you are doing with only factory wiring. The 20-second time-out could be from the Burner circuit - if the burner doesn't light there will be a time out so you don't get a gas explosion. Should just turn off the gas, but killing the main contactor could be an unintended consequence of how they wired it. I know the reason why the RESET popped in 20 seconds. It was because of a short in the remote connection junction box. The RESET button is wired in series with the rest of the control circuit. It is dumb, just a control system circuit breaker. I may have more issues, but for now I need to resolve the wiring issue. i |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Motor rewinding cost | Metalworking | |||
Karcher pressure washer loses pressure... | Home Repair | |||
Pressure washer update | UK diy | |||
Rewinding a motor stator | Electronics Repair | |||
Karcher pressure washer fault (motor?) | UK diy |