Steve B March 20th 06 04:38 AM

I beam fact sheet
 
I want to build an overhead trolley system with a hoist on it. I want to
let one end of the top I beam extend past the support so that it will stick
out over a pickup bed to unload the truck. Where can I find out what the
max load is going to be for the length of stickout for a particular beam?

Steve



Grant Erwin March 20th 06 05:29 AM

I beam fact sheet
 
Steve B wrote:
I want to build an overhead trolley system with a hoist on it. I want to
let one end of the top I beam extend past the support so that it will stick
out over a pickup bed to unload the truck. Where can I find out what the
max load is going to be for the length of stickout for a particular beam?

Steve


This question, phrased variously, comes up all the time. Think for a moment,
Steve, and you will realize that in this litigious society nobody is about to
advise someone on something as risky as overhead beam loading. Then go buy a
steel databook. In the last few years I've picked up a couple, one is the
Ryerson Steel Data Book (very good) and the other is simply titled "Pocket
Companion" by U. S. Steel Corporation, also excellent. Steel handbooks will give
you a good guideline. I can only suggest you build conservatively.

BTW your "stickout" beam is loaded in cantilever, if you search try that term.

GWE

Steve B March 20th 06 05:45 AM

I beam fact sheet
 

This question, phrased variously, comes up all the time. Think for a
moment,
Steve, and you will realize that in this litigious society nobody is about
to advise someone on something as risky as overhead beam loading. Then go
buy a steel databook. In the last few years I've picked up a couple, one
is the Ryerson Steel Data Book (very good) and the other is simply titled
"Pocket Companion" by U. S. Steel Corporation, also excellent. Steel
handbooks will give you a good guideline. I can only suggest you build
conservatively.

BTW your "stickout" beam is loaded in cantilever, if you search try that
term.

GWE


I have a pretty good background in construction and rigging. I generally
figure in a factor of 3 when calculating. So, if I want to lift a maximum
of 500#, I would build it to support over 1500#. It allows for wind and
cerebral flatulence, things that sooner or later are going to occur.

But, now, I can call my steel supplier and ask what is the cantilever info
on X I-beam.

Steve

Steve



Bugs March 20th 06 02:11 PM

I beam fact sheet
 
Ah, just tell him to get a 8" X 16" I beam. That should manage anything
he can get in a pickup! LOL
Bugs


[email protected] March 20th 06 02:39 PM

I beam fact sheet
 
Hoists and cranes for material lifting services are designed with a
factor of safety of 5, based on the ultimate tensile strength of the
steel.

If you want to lift persons the factor of safety is 10, plus a whole
lot of regulatory grief.

Wolfgang


c.henry March 21st 06 12:12 AM

I beam fact sheet
 
Steve B wrote:
I want to build an overhead trolley system with a hoist on it. I want to
let one end of the top I beam extend past the support so that it will stick
out over a pickup bed to unload the truck. Where can I find out what the
max load is going to be for the length of stickout for a particular beam?

Steve


for 6 feet of stick out with a load of 1500 lbs at the end of that stick
out , using a single beam ,

s12x31.8 lb per foot beam

you get .0951 deflection at the end of the beam

you get a max bending stress of 2970 psi at the support 6 feet from end

this is a safty facto of 10


using an 8 inch S8x23 lb per foot

you get .32 inch of deflection at 6 feet with 1500 lbs

the max bending stress is 6660 psi at the last support , this would be a
safety factor of 6 for a 1500 lb load [ about the max in a half ton pick up


the problem is going to be pushing that load up the 3/8 inch deflection hill

if you can build support into the top of the beam and use an underhung
trolly you could safely use a 4- 6 inch beam , but this would take an
engineered support for the top of the beam

also remember that as you load the cantilevered section it will create a
pulling load on the supports past the closest support to the load


also i can email beam boy zips to any body who needs one the web site
seems to be down


i can also design supported beams and engineered gussets if you need them .

no p.e. stamps mind you , that costs more as i have to walk to the end
of the office to have the boss stamp it

Steve B March 21st 06 12:59 AM

I beam fact sheet
 

"c.henry" wrote

a very informative exact answer to my question snipped

Thank you, sir. I have copied this to a file, and will apply it at the
proper time.

Steve



Richard J Kinch March 24th 06 09:05 AM

I beam fact sheet
 
Grant Erwin writes:

in this litigious society nobody is about to
advise someone on something as risky as overhead beam loading.