I was noticed at HD the other day that many of the 220v plugs were 4 wire.
The only kind of plugin device I can think of that might need 4 wire would
be
a dryer. Any others come to mind?

thanks
bill

  #2   Report Post  
Andy S
 
Posts: n/a
Default


"bill a" wrote in message
. com...
I was noticed at HD the other day that many of the 220v plugs were 4 wire.
The only kind of plugin device I can think of that might need 4 wire would
be
a dryer. Any others come to mind?

thanks
bill


An RV that can plug into a 220 volt receptical.


  #3   Report Post  
Joe Bobst
 
Posts: n/a
Default

I was noticed at HD the other day that many of the 220v plugs were 4 wire.
The only kind of plugin device I can think of that might need 4 wire would be
a dryer. Any others come to mind?

Lets turn this around: few 220V appliances, tools, or whatever these days
operate on solely 220V. The majority of things these days have 110V controls,
lamps, whatever, and therefore require a neutral wire. This trend has been
ongoing for some time, so 3-wire plugs will likely be the uncommon type in a
few years just like 2-prong outlets. $0.05 worth...

Joe


  #4   Report Post  
Doug Miller
 
Posts: n/a
Default

In article , "bill a" wrote:
I was noticed at HD the other day that many of the 220v plugs were 4 wire.
The only kind of plugin device I can think of that might need 4 wire would
be
a dryer. Any others come to mind?

Electric range. The heating elements are 220V, but the clock and timer are 110
and thus require a neutral.

  #6   Report Post  
Zypher
 
Posts: n/a
Default

Different configurations for different uses. The UEC doesn't want the wrong
appliance plugged into the wrong circuit. Thus different plugs for
different applications. A 220v four prong (different sizes for different
amperage) 2 legs are hot, one leg is safety ground no-load carrying, and
one leg is load carrying neutral.

--
Zyp
"Doug Miller" wrote in message
. com...
In article , "bill a"

wrote:
I was noticed at HD the other day that many of the 220v plugs were 4

wire.
The only kind of plugin device I can think of that might need 4 wire

would
be
a dryer. Any others come to mind?

Electric range. The heating elements are 220V, but the clock and timer are

110
and thus require a neutral.



  #8   Report Post  
bill a
 
Posts: n/a
Default

thanks
bill

"bill a" wrote in message
. com...
I was noticed at HD the other day that many of the 220v plugs were 4 wire.
The only kind of plugin device I can think of that might need 4 wire would
be
a dryer. Any others come to mind?

thanks
bill


  #9   Report Post  
... ...
 
Posts: n/a
Default

Electric dryer and electric range come to mind for residental
applications. As far as the 110v clocks and timers go most ranges and
dryers have always had them.
The difference between the old three wire and the new for wire is that
in the old set up the ground was being used as the neutral for the 110v
part of the appliance. This setup used the ground as a current carrying
conductor which could cause a problem if the frame of the unit wasn't
grounded
This is no longer allowed under code for new installations. On the 4
wire set ups you have a seperate ground and neural.

Bill

BTW the 30amp 4 wire is for clothes dryers and the 50 anmp is for
ranges,

  #10   Report Post  
ima joker
 
Posts: n/a
Default



Saw a 220V chop saw with a laser that was 110, but it used two
separate cords. Also a lathe with lighted hood, but it was hard-wired
and not plugged.

Jeff


That is a stupid design to have two cords. What maroon designed that??




  #11   Report Post  
Ron
 
Posts: n/a
Default

Ovens

"Andy S" wrote in message
...

"bill a" wrote in message
. com...
I was noticed at HD the other day that many of the 220v plugs were 4

wire.
The only kind of plugin device I can think of that might need 4 wire

would
be
a dryer. Any others come to mind?

thanks
bill


An RV that can plug into a 220 volt receptical.




  #12   Report Post  
john HD
 
Posts: n/a
Default


they are not 220v circuits they are 240v btw.

john


--
john HD
------------------------------------------------------------------------
john HD's Profile: http://homerepairforums.com/forums/member.php?userid=6
View this thread: http://homerepairforums.com/forums/s...ead.php?t=9146
This post was submitted via http://www.HomeRepairForums.org

  #13   Report Post  
Tekkie
 
Posts: n/a
Default

Zypher posted for all of us....

The UEC doesn't want the wrong

WTF is the UEC?
--
Tekkie
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electrical questions on using conduit Wayne Whitney Home Repair 29 September 24th 04 05:56 AM
RCDs on outbuilding circuits 4-LOM UK diy 7 January 31st 04 12:40 AM


All times are GMT +1. The time now is 11:22 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"