I've got a 10 year old Amana refrigerator with the freezer on top.
The original icemaker stopped working.

I have replaced the icemaker and the automatic valve (I have good
water pressure) and the unit(s) do not work.

I've since seen a good bit about testing/replacing the icemaker and
valve. Putting the test jumper does not cause the unit to operate. I
have approximately 50 volts at the connector and right at 120 volts at
the refrigerator outlet. The voltage is also low at the test points
on the icemaker itself. I read somewhere things are OK as low as 80
volts although even that voltage seems low to me and hard to explain.
The refrigerator/freezer/lights operate normally except for the
icemaker.

Based on the simple schematic on the back of the refrigerator I see no
reason for the voltage difference but then it is a simple schematic.
There was ice in the tube that feeds the icemaker so it's
possible/likely the harness got wet but I have used a hair dryer on it
a few times now. I can't really get to the whole harness without
breaking what looks like a seal I should not mess with(unless someone
can tell me how) for a good visual inspection.

I do not have a good feeling about any potential repair people
(including Amana/Maytag) my wife or I have spoken to about the unit
because they keep asking about the all the common stuff I've already
checked. Ideas?
  #2   Report Post  
RS
 
Posts: n/a
Default Amana Icemaker

Remove the ice from the filltube. Check to make sure the icemaker is
securely plugged in.
Do you have the flex-type icemaker or the modular Whirlpool-type icemaker?

It really isn't that complicated and there are only so many things to check.

"Carl J. Mosca" wrote in message
om...
I've got a 10 year old Amana refrigerator with the freezer on top.
The original icemaker stopped working.




I have replaced the icemaker and the automatic valve (I have good
water pressure) and the unit(s) do not work.




I do not have a good feeling about any potential repair people
(including Amana/Maytag) my wife or I have spoken to about the unit
because they keep asking about the all the common stuff I've already
checked. Ideas?


As I said before, it is really a simple device. If you have power, water,
and a cold freezer, you get ice. The 'stuff' they asked you about is the
'stuff' I'd check if I was your serviceman.


  #3   Report Post  
Charlie Bress
 
Posts: n/a
Default Amana Icemaker


"Carl J. Mosca" wrote in message
om...
I've got a 10 year old Amana refrigerator with the freezer on top.
The original icemaker stopped working.

I have replaced the icemaker and the automatic valve (I have good
water pressure) and the unit(s) do not work.

I've since seen a good bit about testing/replacing the icemaker and
valve. Putting the test jumper does not cause the unit to operate. I
have approximately 50 volts at the connector and right at 120 volts at
the refrigerator outlet. The voltage is also low at the test points
on the icemaker itself. I read somewhere things are OK as low as 80
volts although even that voltage seems low to me and hard to explain.
The refrigerator/freezer/lights operate normally except for the
icemaker.

Based on the simple schematic on the back of the refrigerator I see no
reason for the voltage difference but then it is a simple schematic.
There was ice in the tube that feeds the icemaker so it's
possible/likely the harness got wet but I have used a hair dryer on it
a few times now. I can't really get to the whole harness without
breaking what looks like a seal I should not mess with(unless someone
can tell me how) for a good visual inspection.

I do not have a good feeling about any potential repair people
(including Amana/Maytag) my wife or I have spoken to about the unit
because they keep asking about the all the common stuff I've already
checked. Ideas?


Carl, I have an Amana, but I haven't tried pulling it out to see the
schematic. I did look at the instruction sheet for installing the ice maker.
Not much help there.

Unless the schematic shows otherwise the ice maker should be connected to
the line voltage. Some where you are dropping around 80 volts going from the
wall to the icemaker. Wiring in the cable is not the likely problem. What is
more likely is a dirty or corroded connector. Check them all out and clean
if needed. If you have an ohmmeter, unplug the fridge and check for a high
resistance between the fridge ac cord and the icemaker connections. If all
is well the resistance readings should be close to zero. This all assumes
that there is nothing but wire and connectors in the path.

Charlie


  #4   Report Post  
Carl J. Mosca
 
Posts: n/a
Default Amana Icemaker

"RS" wrote in message ...
Remove the ice from the filltube. Check to make sure the icemaker is
securely plugged in.
Do you have the flex-type icemaker or the modular Whirlpool-type icemaker?

It really isn't that complicated and there are only so many things to check.


You are right...it's not that complicated but then what is once you
understand it?

"Carl J. Mosca" wrote in message
om...
I've got a 10 year old Amana refrigerator with the freezer on top.
The original icemaker stopped working.




I have replaced the icemaker and the automatic valve (I have good
water pressure) and the unit(s) do not work.




I do not have a good feeling about any potential repair people
(including Amana/Maytag) my wife or I have spoken to about the unit
because they keep asking about the all the common stuff I've already
checked. Ideas?


As I said before, it is really a simple device. If you have power, water,
and a cold freezer, you get ice. The 'stuff' they asked you about is the
'stuff' I'd check if I was your serviceman.


And that's great but as I told them, I had already checked that stuff.

OK and now for what I was asking about. The reason there was only 50
volts and not 120 at the unit is because there was a corroded wire at
one of the joints in the wire bundle that enters the unit at the top.
In my opinion this is a bad place for such a joint because it was not
very well protected from the moisture which apparently collects there.
I also noticed corrosion in the plug at the bottom of the unit which
I cleaned. As for the joint, I repaired it and now I have 120 at the
test points in the icemaker. Putting the test wire on causes the unit
to operate which is the first time I've seen that (on the new and old
units). I am fairly confident this was the problem because once I
identified the bad joint I jiggled it a bit and got around 80 volts at
the unit. Then I jiggled it a bit more and got 0 volts. At that
point I carefully removed the heat shrink wrap with a razor knife
which revealed one broken wire (red) and a good bit of corrosion on
all three wires along with the crimp type joint.

While listening to the folks on the phone and their "stuff" did cause
me to purchase a non-returnable icemaker and valve I did not need, I
did learn a good bit mostly from surfing the net and the rest from
taking the unit apart.

HTH
  #5   Report Post  
jeff
 
Posts: n/a
Default Amana Icemaker

(Carl J. Mosca) wrote in message . com...
I've got a 10 year old Amana refrigerator with the freezer on top.
The original icemaker stopped working.

I have replaced the icemaker and the automatic valve (I have good
water pressure) and the unit(s) do not work.

I've since seen a good bit about testing/replacing the icemaker and
valve. Putting the test jumper does not cause the unit to operate. I
have approximately 50 volts at the connector and right at 120 volts at
the refrigerator outlet. The voltage is also low at the test points
on the icemaker itself. I read somewhere things are OK as low as 80
volts although even that voltage seems low to me and hard to explain.
The refrigerator/freezer/lights operate normally except for the
icemaker.

Based on the simple schematic on the back of the refrigerator I see no
reason for the voltage difference but then it is a simple schematic.
There was ice in the tube that feeds the icemaker so it's
possible/likely the harness got wet but I have used a hair dryer on it
a few times now. I can't really get to the whole harness without
breaking what looks like a seal I should not mess with(unless someone
can tell me how) for a good visual inspection.

I do not have a good feeling about any potential repair people
(including Amana/Maytag) my wife or I have spoken to about the unit
because they keep asking about the all the common stuff I've already
checked. Ideas?


Hi,

(I have good water pressure)
There was ice in the tube that feeds the icemaker


Low water pressure fills often freezes over the fill tube!!

and the unit(s) do not work


How not work, sits there dead, goes around but not filling, goes part
way through a cycle and quits?

I
have approximately 50 volts at the connector and right at 120 volts at
the refrigerator outlet. The voltage is also low at the test points
on the icemaker itself.


Open/loose neutral can give low/strange readings for power! Open
thermal fuse ( black slug ) in the icemaker harness??

Model#?
http://www.applianceaid.com/model.html
Model# helps.

jeff.

Appliance Repair Aid
http://www.applianceaid.com/


  #6   Report Post  
Carl J. Mosca
 
Posts: n/a
Default Amana Icemaker (Charlie)

Charlie,

Thanks for the help. For some reason I could not post a follow up to
your message which was probably posted about the same time as my
second message in the thread.

As you probably already read, there was a corrosion problem at one of
the connectors (at the bottom). The other, more significant issue,
was the joint at the top of the unit (which I completely missed the
first time I did a visual inspection of the wiring harness). There
are actually multiple joints there so from the looks of things, I'll
be working on this unit again someday.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Amana support pitiful dteckie Woodworking 7 November 13th 03 05:24 PM


All times are GMT +1. The time now is 01:29 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"