Default Thermostat Wiring

So why does a gas furnace control board have a contact for the yellow wire? It makes no sense to me.
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,377
Default Thermostat Wiring

On 07/07/2014 08:55 PM, Davej wrote:
So why does a gas furnace control board have a contact for the yellow wire? It makes no sense to me.




What makes no sense is your vague question
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 404
Default Thermostat Wiring

On Monday, July 7, 2014 9:07:04 PM UTC-5, philo* wrote:
On 07/07/2014 08:55 PM, Davej wrote:

So why does a gas furnace control board have a
contact for the yellow wire? It makes no sense to me.

What makes no sense is your vague question


I think it is because while the green wire or the yellow wire will turn the blower fan on -- the yellow wire will also cause the blower fan to remain on for a minute or so after the compressor turns off.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,586
Default Thermostat Wiring

Davej wrote:
On Monday, July 7, 2014 9:07:04 PM UTC-5, philo wrote:
On 07/07/2014 08:55 PM, Davej wrote:

So why does a gas furnace control board have a
contact for the yellow wire? It makes no sense to me.

What makes no sense is your vague question


I think it is because while the green wire or the yellow wire will turn the blower fan on -- the yellow wire will also cause the blower fan to remain on for a minute or so after the compressor turns off.

Hi,
Y wire is for a/c unit compressor(ODU). Don't use it if you don't have
a/c in your system. Color does not mean much. If you try to match colors
what are going to do when colored wire runs out?
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,377
Default Thermostat Wiring

On 07/07/2014 10:14 PM, Davej wrote:
On Monday, July 7, 2014 9:07:04 PM UTC-5, philo wrote:
On 07/07/2014 08:55 PM, Davej wrote:

So why does a gas furnace control board have a
contact for the yellow wire? It makes no sense to me.

What makes no sense is your vague question


I think it is because while the green wire or the yellow wire will turn the blower fan on -- the yellow wire will also cause the blower fan to remain on for a minute or so after the compressor turns off.




Wire color means nothing , if you want help post a link to the schematic.


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,730
Default Thermostat Wiring

On 7/7/2014 9:55 PM, Davej wrote:
So why does a gas furnace control board have a contact for the yellow wire? It makes no sense to me.


Some applications use it.

--
..
Christopher A. Young
Learn about Jesus
www.lds.org
..
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15,279
Default Thermostat Wiring

On Tuesday, July 8, 2014 7:46:45 AM UTC-4, Stormin Mormon wrote:
On 7/7/2014 9:55 PM, Davej wrote:

So why does a gas furnace control board have a contact for the yellow wire? It makes no sense to me.






Some applications use it.





It's because the typical gas furnace can have AC added as an option.
Yellow is the control wire for AC and the furnace control board runs
both the heat and the AC, if the AC is installed. It's a minimal addition
to the control board circuitry and makes more sense than having two
different versions, one for furnaces with AC and one without.
If there is no AC, then there is no need for connecting a yellow wire.
It might still be done though, to allow for AC in the future.
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 404
Default Thermostat Wiring

On Monday, July 7, 2014 10:14:57 PM UTC-5, Davej wrote:
On Monday, July 7, 2014 9:07:04 PM UTC-5, philo* wrote:
On 07/07/2014 08:55 PM, Davej wrote:

So why does a gas furnace control board have a
contact for the yellow wire? It makes no sense to me.

What makes no sense is your vague question


I think it is because while the green wire or the yellow
wire will turn the blower fan on -- the yellow wire will
also cause the blower fan to remain on for a minute or
so after the compressor turns off.


So perhaps that was at least part of my trouble. When my furnace was installed they did not connect the yellow wire to the furnace control board. Perhaps they were afraid there might be another 24V transformer somewhere and did not want to mess with it. With the yellow wire connected the thermostat now turns off the outdoor A/C compressor and then the blower fan turns off a few minutes later.
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15,279
Default Thermostat Wiring

On Tuesday, July 8, 2014 8:08:01 PM UTC-4, Davej wrote:
On Monday, July 7, 2014 10:14:57 PM UTC-5, Davej wrote:

On Monday, July 7, 2014 9:07:04 PM UTC-5, philo* wrote:


On 07/07/2014 08:55 PM, Davej wrote:




So why does a gas furnace control board have a


contact for the yellow wire? It makes no sense to me.




What makes no sense is your vague question




I think it is because while the green wire or the yellow


wire will turn the blower fan on -- the yellow wire will


also cause the blower fan to remain on for a minute or


so after the compressor turns off.






So perhaps that was at least part of my trouble. When my furnace was installed they did not connect the yellow wire to the furnace control board.



Assuming the wiring followed typical convention, yellow is for AC.
If you have AC, it has to be connected or the AC won't run. If you
don't have AC, then you don't need the yellow wire.




Perhaps they were afraid there might be another 24V transformer somewhere and did not want to mess with it. With the yellow wire connected the thermostat now turns off the outdoor A/C compressor and then the blower fan turns off a few minutes later.


It's not at all clear what's going on here, what was connected, what was
working or not working. But if this was a typical install following wire
colors, the AC would not run without the yellow wire attached to the furnace.
The yellow wire is the call for cooling.
  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,586
Default Thermostat Wiring

trader_4 wrote:
On Tuesday, July 8, 2014 8:08:01 PM UTC-4, Davej wrote:
On Monday, July 7, 2014 10:14:57 PM UTC-5, Davej wrote:

On Monday, July 7, 2014 9:07:04 PM UTC-5, philo wrote:


On 07/07/2014 08:55 PM, Davej wrote:




So why does a gas furnace control board have a


contact for the yellow wire? It makes no sense to me.




What makes no sense is your vague question




I think it is because while the green wire or the yellow


wire will turn the blower fan on -- the yellow wire will


also cause the blower fan to remain on for a minute or


so after the compressor turns off.






So perhaps that was at least part of my trouble. When my furnace was installed they did not connect the yellow wire to the furnace control board.



Assuming the wiring followed typical convention, yellow is for AC.
If you have AC, it has to be connected or the AC won't run. If you
don't have AC, then you don't need the yellow wire.




Perhaps they were afraid there might be another 24V transformer somewhere and did not want to mess with it. With the yellow wire connected the thermostat now turns off the outdoor A/C compressor and then the blower fan turns off a few minutes later.


It's not at all clear what's going on here, what was connected, what was
working or not working. But if this was a typical install following wire
colors, the AC would not run without the yellow wire attached to the furnace.
The yellow wire is the call for cooling.

Hi,
Also there could be 24V AC x-former for cooling and heating separate.
Rc and Rh terminals are usually tied together having one x-former.
Simply consult the user manual for your 'stat for typical wiring example
drawings. No buts, no ifs, just do it right. No exceptions. Blower does
not turn off right away, turn off delay is adjustable.(by jumper or dip
switch) The reason is obvious.


  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,586
Default Thermostat Wiring

Stormin Mormon wrote:
On 7/7/2014 9:55 PM, Davej wrote:
So why does a gas furnace control board have a contact for the yellow
wire? It makes no sense to me.


Some applications use it.

HHm,
Question to OP, would you like two 'stats and two control borads for
your system? One combined dual duty controller and one 'stat, shared
blower. Which do you think is better?
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Greenhouse thermostat wiring spon UK diy 2 January 5th 08 08:53 AM
Need advice on wiring new thermostat Rob Home Repair 6 November 29th 06 10:47 PM
thermostat wiring Al M UK diy 5 November 19th 06 06:26 PM
Wiring Thermostat charlesg Home Repair 6 November 13th 05 01:12 PM
Thermostat Wiring HvacTech2 Home Repair 31 July 13th 05 04:21 PM