Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up.
https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard |
how to brace wall from outside
wrote:
Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up. https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard Maybe I'm missing something. Why do you need to brace it? The windows aren't are bearing any load, so you can take them out without worry. I assume the supports between the windows are bearing a load, unless the header is doing all the work. If the supports between the windows aren't where you need them to be, e.g. 16 or 24" OC, put your other studs in place before removing the existing supports. Am I missing something? |
how to brace wall from outside
On Wednesday, July 2, 2014 7:46:38 PM UTC-4, DerbyDad03 wrote:
wrote: Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up. https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard Maybe I'm missing something. Why do you need to brace it? The windows aren't are bearing any load, so you can take them out without worry. I assume the supports between the windows are bearing a load, unless the header is doing all the work. If the supports between the windows aren't where you need them to be, e.g. 16" or 24" OC, put your other studs in place before removing the existing supports. Am I missing something? +1 I don't see what the need for "external bracing" is either. |
how to brace wall from outside
On Wednesday, July 2, 2014 6:46:38 PM UTC-5, DerbyDad03 wrote:
wrote: Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up. https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard Maybe I'm missing something. Why do you need to brace it? The windows aren't are bearing any load, so you can take them out without worry. I assume the supports between the windows are bearing a load, unless the header is doing all the work. If the supports between the windows aren't where you need them to be, e.g. 16" or 24" OC, put your other studs in place before removing the existing supports. Am I missing something? Hello Derby, That's what I get from rushing a post. I am planning on taking out the beam support and the posts and replacing it with a conventional wall. There are studs sitting on top of that beam going across supporting the roof rafters. I just wanted to make sure that those studs get supported. When I take out that cedar beam, they will be floating. I can brace from the inside to support the ceiling joists, but the studs will need support when I take the wall out. Just wanted to be sure they stay when in put in the top plates (there are no top plates). thanks |
how to brace wall from outside
On Thu, 3 Jul 2014 06:35:35 -0700 (PDT), wrote:
On Wednesday, July 2, 2014 6:46:38 PM UTC-5, DerbyDad03 wrote: wrote: Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up. https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard Maybe I'm missing something. Why do you need to brace it? The windows aren't are bearing any load, so you can take them out without worry. I assume the supports between the windows are bearing a load, unless the header is doing all the work. If the supports between the windows aren't where you need them to be, e.g. 16" or 24" OC, put your other studs in place before removing the existing supports. Am I missing something? Hello Derby, That's what I get from rushing a post. I am planning on taking out the beam support and the posts and replacing it with a conventional wall. There are studs sitting on top of that beam going across supporting the roof rafters. I just wanted to make sure that those studs get supported. When I take out that cedar beam, they will be floating. I can brace from the inside to support the ceiling joists, but the studs will need support when I take the wall out. Just wanted to be sure they stay when in put in the top plates (there are no top plates). thanks Why take out the beam? Is there something wrong with it? If not, just full in the wall below the beam and leave the beam in. |
how to brace wall from outside
wrote:
On Wednesday, July 2, 2014 6:46:38 PM UTC-5, DerbyDad03 wrote: wrote: https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Hello Derby, That's what I get from rushing a post. I am planning on taking out the beam support and the posts and replacing it with a conventional wall. There are studs sitting on top of that beam going across supporting the roof rafters. I just wanted to make sure that those studs get supported. When I take out that cedar beam, they will be floating. I can brace from the inside to support the ceiling joists, but the studs will need support when I take the wall out. Just wanted to be sure they stay when in put in the top plates (there are no top plates). thanks Why do you need to take out the beam? |
how to brace wall from outside
On Thursday, July 3, 2014 9:35:35 AM UTC-4, wrote:
On Wednesday, July 2, 2014 6:46:38 PM UTC-5, DerbyDad03 wrote: wrote: Have a load bearing wall with 4 floor to ceiling windows. I would like to close these up. I can get braces built on the inside. Not sure how to brace from the outside though. It's straight up. https://picasaweb.google.com/1168999...CKbakMjo_u6uLw Pics 1 & 2 are inside views. Pics 3 & 4 are from the outside looking up. Any ideas? thx richard Maybe I'm missing something. Why do you need to brace it? The windows aren't are bearing any load, so you can take them out without worry. I assume the supports between the windows are bearing a load, unless the header is doing all the work. If the supports between the windows aren't where you need them to be, e..g. 16" or 24" OC, put your other studs in place before removing the existing supports. Am I missing something? Hello Derby, That's what I get from rushing a post. I am planning on taking out the beam support and the posts and replacing it with a conventional wall. There are studs sitting on top of that beam going across supporting the roof rafters. I just wanted to make sure that those studs get supported. When I take out that cedar beam, they will be floating. I can brace from the inside to support the ceiling joists, but the studs will need support when I take the wall out. Just wanted to be sure they stay when in put in the top plates (there are no top plates). thanks You don't explain why you want to replace the wall. If all you need to do is remove the windows then remove them and frame the holes. If you really need to remove the beam you will have to support the structure above it. It looks like there is a second story above it? If the second story construction is platform on wall then you can simply build a temporary wall just inside the original wall. If it's something else then you need to figure out exactly what the construction above the beam is before we can give you good advice. |