In BenignBodger writes:

If the drawing is exactly what you have then the red and blue wire have
nothing to do with the motor running -- you could remove them completely
and the motor would still run. Problem is that those two wires 'apply the
brakes' on the motor when the switch is released. Basically the permanent
magnet DC motor acts a generator when unpowered and spinning and shorting
it out sucks up the power it is making bringing it to a semi-screeching
halt. Operating with a freewheeling motor/blade would make the mower less
safe and I certainly wouldn't do it although it would still cut grass.


Ah, you've just answered a related question I had with my (bought
used a year ago) Sears rechargeable battery mower.

(4 by 12V batteries in series - 48 volt)

The batteries caught on fire (yes, really) because.. (insert
a forehead slap here) the wires connecting the batteries
and leading off from them used... friction/slide on tabs.

A lawnmower is pretty much the poster child for vibration.

One wire came just a bit loose, was sparking... hot enough
to set that battery corner on fire...

No major damage, ust that first battery and the one next
to it, and also... the wiring between them and above.

So I put it back together with new batteries but there was
this one "extra" wire I sticking out that I couldn't
figure out where to place. Anyway, I turned on the unit
and it worked fine. Charges up a-ok, too. (oh, I
left the wire in place and capped off the open end).

But now that you've written your note, I realized
that, eyup, the blade keeps spinning a lot longer
now when I release the handle.

- now have to figure out where that wire should have
gone, or maybe just live with it now as is...

--
__________________________________________________ ___
Knowledge may be power, but communications is the key

[to foil spammers, my address has been double rot-13 encoded]


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bridge rectifier formula The Phantom Electronic Schematics 1 July 23rd 08 03:10 PM
six pulse bridge rectifier rex[_3_] Electronics Repair 19 December 15th 07 11:19 PM
Bridge rectifier. John Electronics Repair 8 November 1st 06 07:55 PM
homebuilt welding rectifier: single diode instead of bridge rectifier? [email protected] Metalworking 4 October 30th 05 12:27 AM
Bridge Rectifier Steve Lewinsky Electronics 4 November 24th 03 02:16 AM


All times are GMT +1. The time now is 09:55 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"