I was on the roof one day and noticed lots of heat coming up the
chimney. The furnace is on but hadn't run for several hours. All it can
be is the boiler tubes cooling off and the heat escaping up the chimney.
That heat should be in the house. There should be a cut out deflector on
the stack that puts the exhaust into the basement when the burner is off
thereby retaining the heat inside. It's a terrible waste of heat.


--
LSMFT

I look outside this morning and everything was in 3D!
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Wasted heat

On Sep 28, 5:50*pm, LSMFT wrote:
I was on the roof one day and noticed lots of heat coming up the
chimney. The furnace is on but hadn't run for several hours. All it can
be is the boiler tubes cooling off and the heat escaping up the chimney.
That heat should be in the house. There should be a cut out deflector on
the stack that puts the exhaust into the basement when the burner is off
thereby retaining the heat inside. It's a terrible waste of heat.

--
LSMFT

I look outside this morning and everything was in 3D!


Dampers that close in the flue when the boiler is off have been
standard for new boilers for 10 years that I know of
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 960
Default Wasted heat


"LSMFT" wrote in message
...
I was on the roof one day and noticed lots of heat coming up the chimney.
The furnace is on but hadn't run for several hours. All it can be is the
boiler tubes cooling off and the heat escaping up the chimney. That heat
should be in the house. There should be a cut out deflector on the stack
that puts the exhaust into the basement when the burner is off thereby
retaining the heat inside. It's a terrible waste of heat.


--
LSMFT

I look outside this morning and everything was in 3D!


Our boiler has a automatic flue damper. Opens when burner comes on and
closes when burner turns off. It interlocks with burner so if it fails to
open the burner will not turn on. About 14 years old installation. ww


  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Wasted heat

On Sep 29, 1:22*am, "WW" wrote:
"LSMFT" wrote in message

...

I was on the roof one day and noticed lots of heat coming up the chimney..
The furnace is on but hadn't run for several hours. All it can be is the
boiler tubes cooling off and the heat escaping up the chimney. That heat
should be in the house. There should be a cut out deflector on the stack
that puts the exhaust into the basement when the burner is off thereby
retaining the heat inside. It's a terrible waste of heat.


--
LSMFT


I look outside this morning and everything was in 3D!


Our boiler has a automatic flue damper. Opens when burner comes on and
closes when burner turns off. It interlocks with burner so if it fails to
open the burner will not turn on. About 14 years old installation. *ww


OP needs a new boiler thats 90+ % efficent, in addition the heat seen
MIGHT be from a water heater.........

or the home itself

hot air you spent big bucks to heat naturally exhausts 24/7 from your
chimey

as energy costs rise futher more will get interested in such losses
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,567
Default Wasted heat

On Sep 28, 6:50*pm, LSMFT wrote:
I was on the roof one day and noticed lots of heat coming up the
chimney. The furnace is on but hadn't run for several hours. All it can
be is the boiler tubes cooling off and the heat escaping up the chimney.
That heat should be in the house. There should be a cut out deflector on
the stack that puts the exhaust into the basement when the burner is off
thereby retaining the heat inside. It's a terrible waste of heat.

--
LSMFT

I look outside this morning and everything was in 3D!


Youi can install a automatic damper but you can not install a "cut
out" to the basement.


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2,907
Default Wasted heat

On 9/28/2010 6:50 PM, LSMFT wrote:
I was on the roof one day and noticed lots of heat coming up the
chimney. The furnace is on but hadn't run for several hours. All it can
be is the boiler tubes cooling off and the heat escaping up the chimney.
That heat should be in the house. There should be a cut out deflector on
the stack that puts the exhaust into the basement when the burner is off
thereby retaining the heat inside. It's a terrible waste of heat.



Automatic stack dampers have been standard for quite some time and an
option at least 20 years prior to that.

However you never vent a flue into the basement of living space. The
damper is sufficient because it breaks the draft.
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2,405
Default Wasted heat

On Wed, 29 Sep 2010 05:23:41 -0700 (PDT), "
wrote:

On Sep 29, 1:22Â*am, "WW" wrote:
"LSMFT" wrote in message

...

I was on the roof one day and noticed lots of heat coming up the chimney.
The furnace is on but hadn't run for several hours. All it can be is the
boiler tubes cooling off and the heat escaping up the chimney. That heat
should be in the house. There should be a cut out deflector on the stack
that puts the exhaust into the basement when the burner is off thereby
retaining the heat inside. It's a terrible waste of heat.


--
LSMFT


I look outside this morning and everything was in 3D!


Our boiler has a automatic flue damper. Opens when burner comes on and
closes when burner turns off. It interlocks with burner so if it fails to
open the burner will not turn on. About 14 years old installation. Â*ww


OP needs a new boiler thats 90+ % efficent, in addition the heat seen
MIGHT be from a water heater.........

or the home itself

hot air you spent big bucks to heat naturally exhausts 24/7 from your
chimey

as energy costs rise futher more will get interested in such losses


Real big difference in how new homes *should* be built compared to the
standard older houses - regarding heat loss.
Wasn't given much priority when energy was cheap.
But I bet a lot of the new "McMansions" recently built were put
together sloppily. Just a guess, since I haven't looked at them.

Besides the water heater, the chimney liner and bricks can retain heat
for a while.
I had a new NG furnace (hot air, 80% "efficient") put in 12 years ago
to get central AC in the house, but it has no damper in the flue pipe.
Maybe there's one in the inducer casing.
And my gas water heater has no damper, so now I want to get on the
roof when it's cold out to see what's going on there.
Think there were mechanical dampers on the boiler and water flues in
my last house, both with weighted levers - they were opened by the
heat flow. Those might be illegal now.

Fished a bird out of the inducer casing the first winter after this
furnace was installed, then a couple months later the basement smoke
alarm went off when the water heater would fire up.
Took off the water heater flue to get the well-done squirrel out of
it, then the next day I was on the roof putting a cap on the chimney
liner. The furnace installer had made a big deal of how he was
throwing in a stainless steel chimney liner, but hadn't put a cap on
it.
I heard that squirrel die when the heater kicked on with him stuck in
the pipe, but didn't know it. Thought it was my big CRT computer
monitor going bad with a high pitched electronic scream.
Thinking it was the monitor was unpleasant enough.
Felt real bad about not getting that cap on after the bird fell in.
Would have saved a squirrel to happily live his life chewing on phone
lines and whatever the hell else they do.

Wasted heat is a big subject.
I was a Boilerman in the Navy and we had "economizers" in the stacks
to capture escaping heat.
Always thought about that whenever I felt how hot my furnace flues got
and imagined all the heat escaping up the chimney.
Wanted to get finned flues and rig a fan to blow on them when the
furnace came on, but never bothered doing it.

Aside from bad drafts - including the chimney - and single pane
windows, I think most heat escapes a home right out the walls.
You can pretty easily prevent loss through the attic with a vapor
barrier and a foot of insulation.
But properly insulating walls on an older house can be a problem.
My house was built in 1959. Small brick ranch and well built.
But as far as I know the walls are uninsulated.
Haven't torn off any drywall, but from seeing the switch boxes and
outlets on the outside walls are shallow boxes, and from doing some
drilling for hanging drape hardware and such, it seems the drywall is
fastened to maybe 1x2 furring attached to the bricks.

Since my heating costs are pretty low, it just doesn't seem practical
to tear off everything that is in perfectly good shape and stud and
insulate the walls and deal with window framing.
I've thought about the blow-in insulation, but again it doesn't seem
cost-effective. Might be wrong about that.
Anyway, if I ever had a home built I'd get that double 2x6 staggered
studding and heat with a candle.
I had a '64 Bug and actually laid 4" fiberglass bats on the floor to
make it warmer in the winter.
Don't know if it really made a difference, but I felt warmer (-:

--Vic
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tempstar Heat Pumps secondary heat isn't running during its DefrostCycle usethisone2007 Home Repair 0 February 27th 09 01:22 AM
Private Banking Made Simple - because patsy wasted American Soldiers will just refuse to defend American values - Torture is a crime against God and Humanity. - Bush closed 911 investigations according to the FBI. Gunner Asch[_4_] Woodworking 0 February 9th 09 02:40 AM
Whirlpool electric dryer; problem with heat/thermal cut-offs (no heat) Mike Home Repair 1 August 31st 07 06:34 PM
Buddy tells me if I have elec heat and a heat pump, I can get a deal with PSE&G... dean Home Repair 3 September 26th 05 04:31 AM


All times are GMT +1. The time now is 12:09 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"