Home |
Search |
Today's Posts |
![]() |
|
Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems. |
|
LinkBack | Thread Tools | Display Modes |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Sun, 30 May 2010 15:27:12 -0400, "Existential Angst"
wrote: wrote in message .. . On Sun, 30 May 2010 13:59:01 -0400, "Existential Angst" wrote: wrote in message ... About 6 years ago, we had our kitchen remodelled. We wanted some undercounter lights included. The contractor proposed a low voltage set of lights. I said that I preferred 120 v since I hate humming transformers. He said OK and proceeded to do the job. Fast forward to last summer. We had a nearby lightning strike that took out a lot of stuff - DVRs, various plug-in power supplies, a Davis weather station, a garage door opener, etc. All of that was repaired but a few months later, I noticed the seldomly used undercounter lights didn't work. I started looking for the cause and realized they were low voltage halogens rather than 120v. So basically, there is a transformer somewhere in the kitchen with a blown fuse or winding. I have resigned myself to having to remove some drywall or tile to repair the problem, but I really don't want to use the trial and error method to find the transformer. The lights are near a number of 120 v circuits, but instead of tapping into those circuits, they tied into the circuit for the island. The island has a cooktop and some outlets for portable appliances. All that stuff works. I suppose it is even possible that the transformer is in the island and they ran 12 volt wire under the floor and up the wall to get to the undercounter lights. That wouldn't be how I would do it, but who knows. Between having hardwood floor, a tile backsplash, and granite countertops, the repair won't be easy, but step one is finding the transformer. Any ideas how to find it without tearing apart half the kitchen? Well, by code, things like this can't be in a place without access. If behind drywall, there should be an access panel, the operative word being "should". I agree. "Wands" are pretty available/cheap now, where you connect a signal to the end halogen, and follow it through a headset of sorts, listening for the strength of an audible signal. Really a handy thing to have for sleuthing, altho I forgot the generic term for this particular strategy. Phone guys used to use this all the time, to find the right wire in wired bundles.. Good idea. I will look into that. Maybe I can rent one. I think they're cheap to buy, HF might even have them -- they have $10 clamp-on ammeters. Radio Shack, HD have them, I think. $30?? I just don't know offhand what they're called -- signal tracers, wire tracers, mebbe. OK. I'll look for one at HD or Lowe's. To the other replies: Yes I have a multi-meter - 0 volts coming from the transformer. The bulbs are in parallel. The switch is good. Regarding the possibility of it being a switching power supply, I hadn't thought of that. It could be. If it is, the output filter cap must be shorted since it reads a few tenths of an ohm looking back into the wires from the switch. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Need help finding LCD PCD Manufacturer | Electronics Repair | |||
Finding a breaker | Home Repair | |||
Finding a breaker | Home Repair | |||
Using 3ph transformer as single pahse transformer | Metalworking | |||
Need help finding... | Woodworking |