I notice during heavy rain storms I get leaks between my eavestrough
and the fascia board, the wood board the eavestroughs are connected too, that's called a fascia right? Anyway I noticed it leaks and in some places it drips down as a little stream. Is this normal? If not is this something I fix myself with alot of cauking or do I have to call someone? Thank you |
Water leakage between eavestrough and fascia board
wrote in message ... I notice during heavy rain storms I get leaks between my eavestrough and the fascia board, the wood board the eavestroughs are connected too, that's called a fascia right? Anyway I noticed it leaks and in some places it drips down as a little stream. Is this normal? If not is this something I fix myself with alot of cauking or do I have to call someone? Thank you Your gutters may need cleaning. They may not be able to drain quickly and the gutters are filling up with water and overflowing. Also check your leaders (Downspouts) for clearance as well. If your gutters are installed properly and not falling off, a little bit of the roof should overhang into them. |
Water leakage between eavestrough and fascia board
|
Water leakage between eavestrough and fascia board
Here that is indicative of shoddy workmanship, usually it is becouse
the shingles are started too high up on the roof decking resulting in wicking under the shingle edge. I rectify by slipping leghts of 3 inch angle flashing (10 foot lenghts) which will direct the water directly into the trough. Jesse |
Water leakage between eavestrough and fascia board
On Jul 8, 10:09 pm, Red Green wrote:
" wrote in news:767d4677-536c- : Would not recommend caulk as a solution for any of the above problems. It's a bandaid. Seamless, metal, plastic? Is it leaking only at the gutter length junctions by any chance? Seamless metal. It's leaking along the length of the gutter, not just the junction. If I had to guess I say it is seeping through the puncture whole of those spikes. But I can't tell from down here. These are good suggestions, sounds like I'll have to call some one when I save up some cash. Thank you all |
Water leakage between eavestrough and fascia board
Seamless metal. It's leaking along the length of the gutter, not just the junction. If I had to guess I say it is seeping through the puncture whole of those spikes. Is it standard 3 X 5" seamless gutter ? The water should never get near the top..but should drain faster. First check the drains where the downpipes are connected to the gutter for crud/leaves etc. If they re clean, then what size are your downpipes..I recently saw a Home DIY/Fixit show where they used crappy 2" x 2" downpipe...No good. |