I replaced my flush valve and flapper with an LDR brand. Works great.
There actually seems to be a greater flow into the bowl- not sure why.
Anyway, the problem is a few seconds of water hammer after the toilet
finishes filling and the valve shuts off. Is it because the valve shuts off
too quickly-- is there an adjustment for that or is that the nature of a
valve that doesn't use a ball, but rather an integral float? Would closing
down the feed shutoff valve to lessen the pressure flow to the toilet help?
It would lessen the pressure difference in the line between running and not
running. It doesn't happen when the sink or bathtub are shutoff quickly.
????
Thanks,



  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,300
Default new flush valve-water hammer

Michael Muderick wrote:
I replaced my flush valve and flapper with an LDR brand. Works great.
There actually seems to be a greater flow into the bowl- not sure why.
Anyway, the problem is a few seconds of water hammer after the toilet
finishes filling and the valve shuts off. Is it because the valve shuts off
too quickly-- is there an adjustment for that or is that the nature of a
valve that doesn't use a ball, but rather an integral float? Would closing
down the feed shutoff valve to lessen the pressure flow to the toilet help?
It would lessen the pressure difference in the line between running and not
running. It doesn't happen when the sink or bathtub are shutoff quickly.
????
Thanks,




Try your idea of throttling down the supply shutoff. It'd take a bit
longer to refill the tank, but so what?

If that doesn't work you could always investigate the practicality of
installing a tee and a spring loaded water hammer arrestor behind the
shutoff valve.

http://www.plumbingsupply.com/waterhammerarresters.html

HTH,

Jeff

--
Jeffry Wisnia
(W1BSV + Brass Rat '57 EE)
The speed of light is 1.98*10^14 fathoms per fortnight.
  #3   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default new flush valve-water hammer

On Sun, 22 Jul 2007 06:44:37 GMT, "Michael Muderick"
wrote:

I replaced my flush valve and flapper with an LDR brand. Works great.
There actually seems to be a greater flow into the bowl- not sure why.
Anyway, the problem is a few seconds of water hammer after the toilet


I think that's the price you pay for the greater flow you mention.

finishes filling and the valve shuts off. Is it because the valve shuts off
too quickly-- is there an adjustment for that or is that the nature of a
valve that doesn't use a ball, but rather an integral float? Would closing
down the feed shutoff valve to lessen the pressure flow to the toilet help?


Every situation is different. Why not try it?

I have mine so slow it takes 5 or 10 minutes. But I don't hear a
thing except at the very end.

It would lessen the pressure difference in the line between running and not
running. It doesn't happen when the sink or bathtub are shutoff quickly.
????
Thanks,



  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 134
Default new flush valve-water hammer

IF all else fails, drain your water pipes completely. Sometimes the little
stubs a plumber uses to arrest water hammer gets water logged (the air in
the stub dissolves in the water and disappears). THe quick fix is to drain
the the system and refill so that the air in the stub is restored. The
newer valves close faster than the older ones and cause more water hammer.
Newer addon water hammer arrestors have a bladder in them to keep the air
from mixing with the water.


"Michael Muderick" wrote in message
news1Doi.1383$b04.1196@trndny06...
I replaced my flush valve and flapper with an LDR brand. Works great.
There actually seems to be a greater flow into the bowl- not sure why.
Anyway, the problem is a few seconds of water hammer after the toilet
finishes filling and the valve shuts off. Is it because the valve shuts
off too quickly-- is there an adjustment for that or is that the nature of
a valve that doesn't use a ball, but rather an integral float? Would
closing down the feed shutoff valve to lessen the pressure flow to the
toilet help? It would lessen the pressure difference in the line between
running and not running. It doesn't happen when the sink or bathtub are
shutoff quickly. ????
Thanks,




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
how to replace a flush valve gasket - when you can't fully turn off the water Joe Home Repair 12 July 22nd 07 07:27 AM
Water hammer from central heating valve??? Dave Fawthrop UK diy 8 March 21st 07 07:27 PM
Water hammer when lawn valve turns on Mel Home Repair 2 May 21st 06 08:02 AM
Installed a dual flush toilet cistern outlet valve to save water [email protected] UK diy 0 January 23rd 06 05:51 AM
Installed a dual flush toilet cistern outlet valve to save water [email protected] Home Repair 0 January 23rd 06 05:51 AM


All times are GMT +1. The time now is 12:51 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"