Hello:

I have a question regarding setting the capacity and salt settings on
my water softener, with an Autotrol 460i control unit, and 1 cu ft
resin tank. The control unit allows 3 settings: Capacity, Salt, and
Hardness. I'm assuming Hardness is compensated hardness (manual
doesn't say that, but other posts have mentioned using compensated
hardness for the softener setting). The manual has a chart that shows
multiple capacity settings in kilograins and the recommended salt
setting in pounds for each capacity setting. I don't understand what
the capacity setting should be set to. Is this for the total capacity
that we need to have (i.e. the capacity that is calculated based on
the number of people and usage for each person, etc)??? Also, doesn't
the Salt setting need to always be set to 15 lbs for this size resin
tank (1 cu ft)? I read a post mentioning it needs 15 lbs to
regenerate 1 cu ft of resin. The manual shows different salt values
(15, 8, 6) based on the capacity setting used (30, 24, 20), so that
confused me a little, too.

The whole reason I'm checking the settings is we are using much more
water than we used to (mostly from running the dishwasher and washing
machine a lot more, plus adding 2 kids). I have been noticing more
and more that we run out of soft water before each regeneration
cycle. I checked the brine tank and it seems to be clean and no gunk
on the bottom. Next I had our water retested for hardness & iron, and
am checking the settings on the softener.

Thank you very much for the help.
--
Chris

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default Softener capacity and salt setting

I recommend that you take a look at http://qualitywaterassociates.com/
web site. It helped me a lot and explains how to resolve most of your
questions. The forum is excellant and the company owner is very open
to providing setup information.

While I don't have an Autotrol control valve and since I just went
through this for my Fleck valve, I'll give a shot at some of your
questions. Capacity is the amount of water that can be processed for
a certain hardness water for a given amount of resin (plus enough
reserve to get you to the evening so the system can regenerate.) Salt
setting isn't always the most efficient when set to clean the resin
when the resin is 100% utilized. From memory, you use only 1/2 the
amount of salt when the resin is 75% utilized.

If you are running out of soft water before you regenerate, the
"reserve" is not adequate.

Go to that web site and read up a bit. There is a lot of great
information there.

Paul.

On Feb 6, 12:11 pm, "szilagyic" wrote:
Hello:

I have a question regarding setting the capacity and salt settings on
my water softener, with an Autotrol 460i control unit, and 1 cu ft
resin tank. The control unit allows 3 settings: Capacity, Salt, and
Hardness. I'm assuming Hardness is compensated hardness (manual
doesn't say that, but other posts have mentioned using compensated
hardness for the softener setting). The manual has a chart that shows
multiple capacity settings in kilograins and the recommended salt
setting in pounds for each capacity setting. I don't understand what
the capacity setting should be set to. Is this for the total capacity
that we need to have (i.e. the capacity that is calculated based on
the number of people and usage for each person, etc)??? Also, doesn't
the Salt setting need to always be set to 15 lbs for this size resin
tank (1 cu ft)? I read a post mentioning it needs 15 lbs to
regenerate 1 cu ft of resin. The manual shows different salt values
(15, 8, 6) based on the capacity setting used (30, 24, 20), so that
confused me a little, too.

The whole reason I'm checking the settings is we are using much more
water than we used to (mostly from running the dishwasher and washing
machine a lot more, plus adding 2 kids). I have been noticing more
and more that we run out of soft water before each regeneration
cycle. I checked the brine tank and it seems to be clean and no gunk
on the bottom. Next I had our water retested for hardness & iron, and
am checking the settings on the softener.

Thank you very much for the help.
--
Chris



  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 13
Default Softener capacity and salt setting

On Feb 6, 2:34 pm, wrote:
I recommend that you take a look athttp://qualitywaterassociates.com/
web site. It helped me a lot and explains how to resolve most of your
questions. The forum is excellant and the company owner is very open
to providing setup information.

While I don't have an Autotrol control valve and since I just went
through this for my Fleck valve, I'll give a shot at some of your
questions. Capacity is the amount of water that can be processed for
a certain hardness water for a given amount of resin (plus enough
reserve to get you to the evening so the system can regenerate.) Salt
setting isn't always the most efficient when set to clean the resin
when the resin is 100% utilized. From memory, you use only 1/2 the
amount of salt when the resin is 75% utilized.

If you are running out of soft water before you regenerate, the
"reserve" is not adequate.

Go to that web site and read up a bit. There is a lot of great
information there.

Paul.



Thank you for the info... I got the info from www.qualitywaterassociates.com
and am good now. I figured I'd post the answers to my questions in
this thread in case others find it. Here's what I did:

The Capacity Setting that you put in the softener can be calculated
from the formula:

Capacity = (Number of People) * 60 * (Compensated Hardness) * 8

Compensated Hardness = (Raw hardness) + ((Iron ppm) * 4) + ((Manganese
ppm) * 2)

I ended up putting the Compensated Hardness number in the softener's
control valve (440i), not the Raw Hardness (reading that you get from
the water test). I am assuming this is what should be done since the
softener doesn't know what the iron and manganese amounts are unless
you account for them in the hardness value.

The Salt Setting varies depending on the size of resin tank you have.
The softener manual should tell you want Salt Setting to use for the
Capacity Setting you use, for your size resin tank.

Then Gary @ qualitywaterassociates.com recommends setting the Calendar
Override setting (if your softener supports it) to 8 days. This
forces the softener to run after 8 days regardless, as he mentions it
is not good to run it longer than that.

If you have 2 ppm of iron or more, you can divide the Capacity Setting
and Salt Setting in half, and put those values in to the softener.
Then set the Calendar Override setting to 4 days. This forces the
softener to regenerate more frequently.

I hope this helps. Check out http://www.qualitywaterassociates.com
for further info.

Thanks,
--
Chris

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rainsoft water softener. Not using any salt? [email protected] Home Repair 8 May 21st 16 07:44 PM
How Much Salt Does a Softener Use? gmark Home Repair 6 January 22nd 07 10:12 PM
How Much Salt Does a Softener Use? Sudy Nim Home Repair 5 January 21st 07 07:07 PM
Water softener using too much salt. [email protected] Home Repair 5 November 22nd 05 04:20 PM
Water Softener Capacity Nav Home Ownership 1 January 25th 05 05:06 AM


All times are GMT +1. The time now is 12:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"