Default Heating System Noise

We have a forced hot air system that is about 12 years old.
Occasionaly when the blower starts up I hear a rattling noise that gets
increasing louder and then fades away. ANy suggestions on what might
be causing this? something loose? what usually wears out to cause
this and where/how should I diagnose. Thanks

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 557
Default Heating System Noise

On 5 Jan 2007 13:14:29 -0800, "MB" wrote:

We have a forced hot air system that is about 12 years old.
Occasionaly when the blower starts up I hear a rattling noise that gets
increasing louder and then fades away. ANy suggestions on what might
be causing this? something loose? what usually wears out to cause
this and where/how should I diagnose. Thanks



Could be a bearing rubbing, but then this would be just guessing. Have
a professional check it out, since it could be cheaper now than a
repair later.

imho,

tom @ www.FreelancingProjects.com

  #3   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default Heating System Noise

On 5 Jan 2007 13:14:29 -0800, "MB" wrote:

We have a forced hot air system that is about 12 years old.
Occasionaly when the blower starts up I hear a rattling noise that gets
increasing louder and then fades away. ANy suggestions on what might
be causing this? something loose? what usually wears out to cause
this and where/how should I diagnose. Thanks


I haven't heard your noise but it could be the blower fan blade,
either the collar loose on the shaft or the blade (maybe a squirrel
cage) loose on the collar.

For some strange reaso;n I couldn't get my motor out the first try,
and since I had to go on a business trip in a couple days, I called a
repair company. The joker changed the motor and reused the blade.
When I told him that it was just as noisy as it had been, he denied
it, but he was wrong. And stupid or lying.

He took the motor away, but I called the office 20 minutes later when
I realized this, and I got the motor back. I complained to them but
got nowhere. Years later the head of the company said I should have
complained to him directly, and although I don't know if it would have
helped or not, I should have, if only so I could write a better story
here.

Anyhow, since I now knew it was only the blade loose on the collar, I
wasn't worried about a fire starting while I was out of town for
almost a week. Got back around early January, and a couple weeks later
the noise stopped. It was quiet and ok for a couple years, and then
it got much worse and I had to buy a new blade. I still have the
motor. Maybe I'll use it for a bench tool, or in case the new motor
fails.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default Heating System Noise

I had the same problem with the furnace here.

The rattling comes very *likely* from worn out bearings of the blower-motor,
and/or the squirrel-cage blower might be out of balance.
There might also be the option that only a screw is loose.

In my case there was significant play, try carefully to slide the
shaft/motor w/ the squirrel cage left and right if there is any play.
Here it was so bad that the blower actually touched the side of the
housing..therefore creating the rattling noise.

I'd defintly let an HSV guy let that check out. Other option would be DiY
which would mean getting the whole housing w/ the cage out, checking the
motor, screws, bearings...even cleaning the cage with a hose or replacing
the blower, maybe even the whole motor.

Greetings
--
http://www.reconditioned-power-tools.com - Reconditioned and Refurbished
Power Tools



"MB" wrote in message
ps.com...
We have a forced hot air system that is about 12 years old.
Occasionaly when the blower starts up I hear a rattling noise that gets
increasing louder and then fades away. ANy suggestions on what might
be causing this? something loose? what usually wears out to cause
this and where/how should I diagnose. Thanks



  #5   Report Post  
Posted to alt.home.repair
mm mm is offline
external usenet poster
 
Posts: 7,824
Default Heating System Noise

On Sun, 7 Jan 2007 03:47:08 -0600, "Georg" wrote:

I had the same problem with the furnace here.

The rattling comes very *likely* from worn out bearings of the blower-motor,


That was probably what my guy thought, and though I believe you that
the odds were with that reason, in my case, he probably didn't even
listen to the sound, or he would have known it wasn't bearings. I
think I knew it wasn't bearings, but I was young and trusting, and
figured I didn't have to question him before he started replacing
things.

and/or the squirrel-cage blower might be out of balance.
There might also be the option that only a screw is loose.

In my case there was significant play, try carefully to slide the
shaft/motor w/ the squirrel cage left and right if there is any play.
Here it was so bad that the blower actually touched the side of the
housing..therefore creating the rattling noise.

I'd defintly let an HSV guy let that check out. Other option would be DiY
which would mean getting the whole housing w/ the cage out, checking the
motor, screws, bearings...even cleaning the cage with a hose or replacing
the blower, maybe even the whole motor.

Greetings


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
New heating system - radiator noise john51 UK diy 3 December 29th 06 01:40 PM
Grinding noise in Toro self-propel system tomkanpa Home Repair 1 July 8th 06 09:23 PM
Central Heating Bypass on Fully TRV'd SYstem (Incl Honeywell CM37z Zone System) t UK diy 10 April 3rd 06 06:53 PM
Ticking noise from Aiwa compact cd system Adrian Brentnall Electronics Repair 4 December 24th 04 09:05 AM
mains Hot water, and do I convert open heating to a closed heating system Ian Tracey UK diy 5 July 18th 03 09:55 AM


All times are GMT +1. The time now is 11:01 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"