Gas range dont always ignite
I have a gas range and the automatic igniter does not always click
(spark). When it clicks, it lights, but half the time it does not click. This is on ALL 4 burners. What should I check? All tips appreciated. I'm not real familiar with them. (Yes, I am turning it to the correct position for lighting). The range is a Lady Kenmore (I think it's about 6 to 8 years old) The rest of the range works fine. It's on propane, which does not really matter. Thanks Mark |
Gas range dont always ignite
|
Gas range dont always ignite
On Sat, 26 Nov 2005 11:03:49 GMT, "Joseph Meehan"
wrote: wrote: I have a gas range and the automatic igniter does not always click (spark). When it clicks, it lights, but half the time it does not click. This is on ALL 4 burners. What should I check? All tips appreciated. I'm not real familiar with them. (Yes, I am turning it to the correct position for lighting). The range is a Lady Kenmore (I think it's about 6 to 8 years old) The rest of the range works fine. It's on propane, which does not really matter. Thanks Mark Buried somewhere (mine is the very back bottom right side) is the transformer that provides the high voltage for the spark. Chances are it is going out. It could also be a wiring problem, but I would guess that would not work sometimes and not others. Thanks Joseph I will see what I can find. I was wondering if there could be a problem with the *switch* that is supposed to start the spark, but since it's on ALL burners, I assume each has it's own. Guess I will have to just dig into it. Any idea what the voltage is coming from that transformer? I may be able to rip one out of an old stove that I am planning to the dump. (different brand, but if I can mount it, I would guess it would work, because that stove always lit). Mark |
Gas range dont always ignite
I will see what I can find. I was wondering if there could be a
problem with the *switch* that is supposed to start the spark, but since it's on ALL burners, I assume each has it's own. Guess I will have to just dig into it. Any idea what the voltage is coming from that transformer? I may be able to rip one out of an old stove that I am planning to the dump. (different brand, but if I can mount it, I would guess it would work, because that stove always lit). If it's similar to the Kitchenaid cooktop I am familar with each gas valve does indeed have its own switch but two spark gaps are each shared by two burners. With the same problem on all burners the switches are probably not to blame. The HV source is not a transformer per se but a spark generating module. It's similar to what is used on many gas furnaces except that those are usually 24 VAC in while the stove's probably runs directly on 120 VAC. The one from the old stove will probably work just fine. Don't zap yourself. |
Gas range dont always ignite
|