Posts: n/a
Default installing water supply line from street to house.

Asking this for a neighbor setting up his mountain property mobile
home.
He wants to do this all himself...
Needs to install 200 ft of line from the meter to house. He was going
to use ordinary
PVC so that would mean about 20 coupling joints that could fail. I know
Copper is best
but he could never solder it. I had mine replaced and they used Pvc
material with a flared
end on one end of each piece so no couplers needed. one piece slid into
the other then
was glued. I dont know what that pipe is called but I think it was
rated at 450psi..
Any suggestions? I told him to dig the trench and get a pro out there.

  #2   Report Post  
Colbyt
 
Posts: n/a
Default installing water supply line from street to house.


wrote in message
ups.com...
Asking this for a neighbor setting up his mountain property mobile
home.
He wants to do this all himself...
Needs to install 200 ft of line from the meter to house. He was going
to use ordinary
PVC so that would mean about 20 coupling joints that could fail. I know
Copper is best
but he could never solder it. I had mine replaced and they used Pvc
material with a flared
end on one end of each piece so no couplers needed. one piece slid into
the other then
was glued. I dont know what that pipe is called but I think it was
rated at 450psi..
Any suggestions? I told him to dig the trench and get a pro out there.


Most rural locations around here use the black hose (Poly?, not sure of the
composition). Means no underground joint for most runs. Use clamps at each
end to convert to regular fittings.

I put one of these in in 1969 for my grandparents and it is still working
today.

Colbyt


  #3   Report Post  
buffalobill
 
Posts: n/a
Default installing water supply line from street to house.

if the water meter is subject to freezing he'll want to send some
underground wire down the trench for a heater circuit. don't forget an
extra circuits for the doorbell, gate, camera, cable tv, intercom, wild
animal sensors...

when trenching call the underground line companies, for
gas-water-electric existing lines to be marked so there is no danger
from the trenching contractor. checking with the neighbors to see if
their water lines freeze may help him plan to go deeper than he
thought.

see also plumbing codes for your particular state-county-town. hiring a
local plumber who already knows all this would be worth it,
and he can follow the plumber's instructions.

a local old-timer expert is needed.

  #4   Report Post  
TURTLE
 
Posts: n/a
Default installing water supply line from street to house.

This is Turtle.

Hey the biggest part of the job is digging the holes. Then get him like
Colbyt said get the 20 foot joints with coupling already on them. This
would be only 10 coupling and learn how to make glue joints before
starting. Also use the wet or dry glue and turn on pressure before
covering up pipe to trailor to check for leaks. Also put it " deep
below " the frost line if you can.

TURTLE

  #5   Report Post  
 
Posts: n/a
Default installing water supply line from street to house.

Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.



  #6   Report Post  
wkearney99
 
Posts: n/a
Default installing water supply line from street to house.

Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.


Bear in mind that by following local code and getting a permit the line will
presumable also end up registered in the digging database.

I can't imagine that it's legal to run a house supply from the municpal
water service without getting a permit for it. Don't half-ass it here, get
a permit, follow the code and just avoid the eventual headaches.

  #7   Report Post  
Colbyt
 
Posts: n/a
Default installing water supply line from street to house.


wrote in message
oups.com...
Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.


Turtle was just recommending the 20 foot section of PVC pipe that have an
attached coupler to one end. This is commonly used in irrigation systems.
No reason it would not work.

What I recommended in my earlier post is sold in big rolls and you would
have no gluing to do. It may or may not be legal in your area. It is sold
a plumbing supply stores and "farm and ranch" stores like Southern States if
you have them in Georgia.


Colbyt


  #8   Report Post  
George E. Cawthon
 
Posts: n/a
Default installing water supply line from street to house.

Colbyt wrote:
wrote in message
oups.com...

Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.



Turtle was just recommending the 20 foot section of PVC pipe that have an
attached coupler to one end. This is commonly used in irrigation systems.
No reason it would not work.

What I recommended in my earlier post is sold in big rolls and you would
have no gluing to do. It may or may not be legal in your area. It is sold
a plumbing supply stores and "farm and ranch" stores like Southern States if
you have them in Georgia.


Colbyt



The same type of stuff is used around here, not
only for irrigation, but also for domestic supply.
It is recommended in some places where
electrolytic processes eat holes in copper. The
slightly more expensive stuff has a heavier wall
ad is rated at about 140 psi. Can't come close to
the 30 years for your grand-parents, My father
used it to run a long line to irrigated an area
located about 300 feet from the supply with an
intervening forest. So he just laid it on the
ground. I suppose he drained it each winter since
it gets down below 0 regularly. I ran a buried
line for irrigation and then built shed with a
concrete pad above it. Of course the automatic
drain didn't and the line froze and broke beneath
the concrete pad. So I just ran a line on top of
the ground. I thought the sun would deteriorate
it quickly but it is still fine after more than 15
years. I wouldn't hesitate to use it for a water
supply line.
  #9   Report Post  
Harry K
 
Posts: n/a
Default installing water supply line from street to house.


wrote:
Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.


No special name that I am aware of, just PVC. I have a 1/4 mile run I
put in back in 1977 or 78 and have had no problems with it. Any
regular plumbing shop will have it in 20 ft lengths. I am surprised
that the big box stores don't have it also. It is cheap, easy to work
with and durable. Do go with the schedule 80 not sched 40. 80 is the
heavy wall. Not really needed but the peace of mind is worth it. In
any case PVC is not a high dollar item.

Be absolutely sure that when he transitions from iron (copper) or
whatever that he uses a Female Iron to a male PVC. Doing it the other
way can cause the fitting to split on the casting line. Things you
learn the hard way like I did.

Harry K

Harry K

  #10   Report Post  
MC
 
Posts: n/a
Default installing water supply line from street to house.

Harry K wrote:
wrote:

Thanks Turtle, is there a special name for that type of PVC pipe?
Not to be found at Home Depot, I checked. I guess a real plumbing
supply place.
Here in Georgia we dont have to go too deep to stop freezing but
deeper is better. Yes test before backfilling hole for sure.
This was pasture land and there is no gas lines, no underground
electric
No underground cable, no telephone lines, etc but would not hurt to
check
for free.



No special name that I am aware of, just PVC. I have a 1/4 mile run I
put in back in 1977 or 78 and have had no problems with it. Any
regular plumbing shop will have it in 20 ft lengths. I am surprised
that the big box stores don't have it also. It is cheap, easy to work
with and durable. Do go with the schedule 80 not sched 40. 80 is the
heavy wall. Not really needed but the peace of mind is worth it. In
any case PVC is not a high dollar item.

Be absolutely sure that when he transitions from iron (copper) or
whatever that he uses a Female Iron to a male PVC. Doing it the other
way can cause the fitting to split on the casting line. Things you
learn the hard way like I did.

Harry K

Harry K


Pipe with the end that is bigger so no unions are needed is called bell end.
I use 20ft sections with bell ends and never had a leak yet.

Trench down below the frost line, prep the ends being glued well by
wiping clean, use primer before glueing. also wipe clean and prime the
inside of the bell end. pressure test before covering up pipe.

I would use 1 inch PVC pipe for 200 ft.

Also if coming from street, depending on pressure, may need a regulator.
If you do put at the house. When I bought my house some idiot decided to
put the regulator in the meter box at the street and my house is 300ft
away with 3/4 pipe (was the blue junk), no pressure. replaced with 1
inch PVC, regulator moved to the house. street pressure about 100psi and
house nice 55psi. now I can flush and does not affect the shower.

I have run many thousond feet of PVC up to 2inch for irrigation under
ground at my parents farm with no issues.

MC
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
AquaTherm Furnace - No Hot Water Issue David Home Repair 11 January 25th 18 08:44 PM
Tankless water heaters Edward Grant Home Repair 11 September 13th 05 12:42 AM
Power Supply Repair fernando1222 Electronics Repair 0 June 7th 05 09:18 PM
I need a little advice on running waterlines in an uninsulated crawlspace ozark Home Repair 12 January 29th 04 05:23 AM
Why is this a bad idea? Mike Hibbert UK diy 18 August 28th 03 11:59 PM


All times are GMT +1. The time now is 05:58 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"