Please don't laugh at the silly question, but what component should I
buy to reduce the power output of a transformer from 26.4 volts, down
to 24 ?

This is an AC transformer that supplies power to the circuit board of
a home heating furnace. It takes line voltage in on one end and should
have an output of 24 Volts AC.

Two wires in, two wires out; grounding through its metal case. The
actual voltage going in is 118v and the output is 26.4v to 27.4v (two
voltmeters used).

The circuit board feeds the thermostat (among other things) and the
output on the thermostat leads is 27.11v

Do I need to install a resistor? If yes, what capacity?

  #2   Report Post  
Edwin Pawlowski
 
Posts: n/a
Default How to get 24 v AC from 27 ?

Michael Stoic wrote:
Please don't laugh at the silly question, but what component should I
buy to reduce the power output of a transformer from 26.4 volts, down
to 24 ?

This is an AC transformer that supplies power to the circuit board of
a home heating furnace. It takes line voltage in on one end and should
have an output of 24 Volts AC.


How do you know it is truly 26.4 volts? Maybe your meter is off. Besides,
a plus or minus is always normal. Don't lose any sleep.
--
Ed
http://pages.cthome.net/edhome/


  #3   Report Post  
FDR
 
Posts: n/a
Default How to get 24 v AC from 27 ?


"Michael Stoic" wrote in message
...
Please don't laugh at the silly question, but what component should I
buy to reduce the power output of a transformer from 26.4 volts, down
to 24 ?

This is an AC transformer that supplies power to the circuit board of
a home heating furnace. It takes line voltage in on one end and should
have an output of 24 Volts AC.

Two wires in, two wires out; grounding through its metal case. The
actual voltage going in is 118v and the output is 26.4v to 27.4v (two
voltmeters used).

The circuit board feeds the thermostat (among other things) and the
output on the thermostat leads is 27.11v

Do I need to install a resistor? If yes, what capacity?


Once you put a load across the transformer output it will probably drop a
bit. I'm sure that 24 volts +/- 10% will be ok.


  #4   Report Post  
TURTLE
 
Posts: n/a
Default How to get 24 v AC from 27 ?


"Michael Stoic" wrote in message
...
Please don't laugh at the silly question, but what component should I
buy to reduce the power output of a transformer from 26.4 volts, down
to 24 ?

This is an AC transformer that supplies power to the circuit board of
a home heating furnace. It takes line voltage in on one end and should
have an output of 24 Volts AC.

Two wires in, two wires out; grounding through its metal case. The
actual voltage going in is 118v and the output is 26.4v to 27.4v (two
voltmeters used).

The circuit board feeds the thermostat (among other things) and the
output on the thermostat leads is 27.11v

Do I need to install a resistor? If yes, what capacity?


this is Turtle.

Michael , i've done this hvac work all my life and the voltage of the gas
furnaces is called 24 volt ac but ranges from 20 volts to 28 volts ac. The
transforner that puts out the 24 volts ac normally for the gas furnaces with out
no load on it will normally put out 26 to 28 volt ac. With a load on them from
the gas furnace and cooling system running . it could run the voltage down to 17
or18 volts. So if you have a 28 volt ac without a load on it, that is very
good.

Michael , your good to go but just don't know it.

TURTLE


  #5   Report Post  
Michael Stoic
 
Posts: n/a
Default How to get 24 v AC from 27 ?



OK, I've made my peace with it. Thank you for your help!

..MS

On Wed, 26 Oct 2005 03:31:26 GMT, "FDR"
wrote:


"Michael Stoic" wrote in message
.. .
Please don't laugh at the silly question, but what component should I
buy to reduce the power output of a transformer from 26.4 volts, down
to 24 ?

This is an AC transformer that supplies power to the circuit board of
a home heating furnace. It takes line voltage in on one end and should
have an output of 24 Volts AC.

Two wires in, two wires out; grounding through its metal case. The
actual voltage going in is 118v and the output is 26.4v to 27.4v (two
voltmeters used).

The circuit board feeds the thermostat (among other things) and the
output on the thermostat leads is 27.11v

Do I need to install a resistor? If yes, what capacity?


Once you put a load across the transformer output it will probably drop a
bit. I'm sure that 24 volts +/- 10% will be ok.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 04:02 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"