Home |
Search |
Today's Posts |
![]() |
|
Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems. |
|
LinkBack | Thread Tools | Display Modes |
#1
![]() |
|||
|
|||
![]()
Hello:
Boy, I have just finished spending several hours trying to figure out what is wrong, and am still stumped. Would really be most appreciative for any thoughts on the following: My son moved into a 30 year old house a few weeks back. The house has 3 AC wired-in Rittenhouser smoke alarms. (anyone ever hear of these, or possibly know what voltage is supposed to appear on the red interconnect wire when tripped ?) No real way of knowing, but it wouldn't surprise me if they were originally put in when the house was built, some 30 years back. But they are possibly newer ? The three units apparently are wired to communicate with each other; I guess that if one goes off, they all are supposed to go off. They have a third, Red, wire daisy chaining from one to another. Didn't really think they did this daisy-chaining concept to fairly recently, so was a bit surprised to see it. I just put in 3 new Kidde Model PI 2000 (dual, photoelectric/ionization) alarms. Also AC wired in. The "seem" to work fine. But, if I hook up the red wires to daisy chain them together, they all keep going off, sequentially. Disconnecting the red wires, reverts them back to apparently normal operation. The house is a bit far from me, and won't be down there again for a week or two. I mention this, because I "now" think that it might have been a good idea to put a meter on the red wire and check if there is any voltage on it ? My undertstanding with the Kidde units, although I am not really sure, is that there should normally not be any voltage on the red wires (relative to ground) unless one of the units is tripped. Should have checked. Guess I assumed that the daisy chaining "concept" would be the same for the old units as it is for the new ones ? ** Is it possible that these old Rittenhouser units have the red, daisy link, wire always hooked up to some voltage, or...? ** Am I possibly missing anything when I wired them in ? Any thoughts on what might bwe the problem, and how to correct it would be most appreciated. Thanks, Bob |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Disable leg of gang-trip smoke detectors | Home Repair | |||
PLUG-IN SMOKE DETECTORS | Home Repair | |||
Strange not-quite-240 high-voltage smoke problem... short? circuit breaker? | Home Repair | |||
Problem with retrace lines on EIZO F55S... | Electronics Repair | |||
Linked Mains Smoke Detectors | UK diy |