metal halide bulbs testing?
Hi all, I have an sharp XG-E3500U lcd projector that i'm trying to repair,
I've purchased a copy of the service manual (email me off list if you'd like a copy) and have a pretty good idea of how things are working. when i got the unit, the main fuse on the power board was blown and the person who gave it to me suspected that the power supply was bad. when i replace the fuse and power up, the lamp arcs 2-3 but never lights. the fuse blows immediately afterward. my assumption is that either the warm-up arc isn't able to ignite the lamp because it's bad, or that the lower voltage componant supplied by the ballast is isn't there so the thing keeps pulsing then blows a fuse. Will a bad bulb cause a fuse to blow because it won't conduct a current after being hit with the warm up arc? I figured I'd send a message to the list to get an opinion before i spend $300 on a new bulb.. maybe i need to focus more on trouble shooting the ballast. Is there an easy check for visual or electronic signs of a bad metal halide bulb? Thanks for any help, Steve p.s., please don't warn me about the high voltage.. i may sound like a novice but my heart is healthy and i'm quite intent on getting this thing to work. |
#2
|
|||
|
|||
"Steve Vitale" wrote in message ... | Hi all, I have an sharp XG-E3500U lcd projector that i'm trying to repair, | I've purchased a copy of the service manual (email me off list if you'd | like a copy) and have a pretty good idea of how things are working. when i | got the unit, the main fuse on the power board was blown and the person | who gave it to me suspected that the power supply was bad. when i replace | the fuse and power up, the lamp arcs 2-3 but never lights. the fuse blows | immediately afterward. my assumption is that either the warm-up arc isn't | able to ignite the lamp because it's bad, or that the lower voltage | componant supplied by the ballast is isn't there so the thing keeps | pulsing then blows a fuse. Will a bad bulb cause a fuse to blow because it | won't conduct a current after being hit with the warm up arc? I figured | I'd send a message to the list to get an opinion before i spend $300 on a | new bulb.. maybe i need to focus more on trouble shooting the ballast. Is | there an easy check for visual or electronic signs of a bad metal halide | bulb? Thanks for any help, Steve That's backwards. I'd suspect the ballast, not the lamp. Is the ballast inductive or solid state? I'd try hooking up a 100 W light bulb as a test to replace the lamp, disconnecting the starter system if possible. If the lamp glows fully or not at all I'd suspect the ballast. N |
#3
|
|||
|
|||
That's backwards. I'd suspect the ballast, not the lamp. Is the ballast
inductive or solid state? I'd try hooking up a 100 W light bulb as a test to replace the lamp, disconnecting the starter system if possible. If the lamp glows fully or not at all I'd suspect the ballast. N I assume that it's an electronic ballast as it uses transistors to limit current as opposed to a coil. i assume those should be keeping things from reaching a current where a fuse would blow? i think this is starting to make a bit more sense. Thanks |
#4
|
|||
|
|||
"Steve Vitale" wrote in message ... | That's backwards. I'd suspect the ballast, not the lamp. Is the ballast | inductive or solid state? I'd try hooking up a 100 W light bulb as a test to | replace the lamp, disconnecting the starter system if possible. If the lamp | glows fully or not at all I'd suspect the ballast. | | N | I assume that it's an electronic ballast as it uses transistors to limit | current as opposed to a coil. i assume those should be keeping things | from reaching a current where a fuse would blow? i think this is starting | to make a bit more sense. | Thanks Much more likely one of those has punched through. Replace them or find a way to test them under voltage. N |
#5
|
|||
|
|||
"Steve Vitale" wrote in message ... That's backwards. I'd suspect the ballast, not the lamp. Is the ballast inductive or solid state? I'd try hooking up a 100 W light bulb as a test to replace the lamp, disconnecting the starter system if possible. If the lamp glows fully or not at all I'd suspect the ballast. N I assume that it's an electronic ballast as it uses transistors to limit current as opposed to a coil. i assume those should be keeping things from reaching a current where a fuse would blow? i think this is starting to make a bit more sense. Thanks If the fuse blows you have a problem with the ballast. An electronic ballast still uses a transformer, it's more like a switching power supply in a PC, monitor, etc, but rather than regulate the output voltage it regulates the amperage as well as provides a high voltage spike to strike the arc. Check carefully for shorted semiconductors in the ballast circuit. |