Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
|
|||
|
|||
mitsubishi vs-5043
Hello,
My sister's, who's living abroad, has a vs-5043 that won't turn on. after clicking the power button, it will turn on and turn off instantly. Any idea? much appreciated. |
#2
|
|||
|
|||
Power supply, deflection problems, probably a lot of electrolytic caps going
south. Best to have a service company that is familar with these sets to address it. "Hythum Kiswani" wrote in message m... Hello, My sister's, who's living abroad, has a vs-5043 that won't turn on. after clicking the power button, it will turn on and turn off instantly. Any idea? much appreciated. |
#3
|
|||
|
|||
VZ3 chassis, 1996. Not a lot of bad caps in these. Many coolant leaks.
Basic troubleshooting necessary on this one. Leonard "Hythum Kiswani" wrote in message m... Hello, My sister's, who's living abroad, has a vs-5043 that won't turn on. after clicking the power button, it will turn on and turn off instantly. Any idea? much appreciated. |
#4
|
|||
|
|||
We have found the following electrolytic caps causing this problem in
several VS-5043's: C5A28 100uf 200v (behind flyback), C936 1000uf 16v in pwr supply, C5A19 100uf 16v near MS plug. Hope it helps you out, -Mike |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair | |||
ATT; Hobbyists and Repairmen I have accumulated a room of ICS, Transistors, Diodes , Mem Chips , Proms etc | Electronics Repair |