On Tue, 08 Jul 2003 05:23:26 +1000, Bob Parker wrote:
"Asimov" wrote: "Lenny" wrote to "All" (06 Jul 03 09:02:29) --- on the topic of "Low ohms, (Dick Smith ESR meter), measurement problems" The ESR meter uses something like 100KHz AC signal frequency. You are bound to fool it with the long wires's inductive reactance! The dc meter has no such reactive problems. Asimov ****** G'day, My little reactance calculator says that it only takes about 40uH of inductance to give a reactance of 26 ohms at 100kHz, which is approximately the effective measurement frequency of the DSE ESR meter. Long lengths of wire in a building would easily have 40uH of inductance. ![]() Sorry the meter led you astray, Lenny. It was only ever meant for testing electrolytic caps and measuring low resistances which don't have a significant amount of series inductance. One place where that characteristic is really helpful is with some of the small toroidal trannies in switching supplies. Shorted ones and good ones look about the same to your average bench DC Ohmmeter. They look radically different on the DS ESR meter. Ron |