N_Cook April 13th 14 11:51 AM

SMPS failure query
 
In a Philips CDR755, year 2000. Working fine previous time of use and
then nothing at the next use. Turned out to be a 1N5406 size package
SB360 3amp 60V shottky diode gone short circuit on the LV side for the
5V rail. No other colateral damage (not tried recording a CD yet but
both decks play) , maybe a very slight discolouration on the anode end
of the diode, could equally be from time of encapsulation. After the Tx
, I would have said probability-wise. about the least likely item to
fail. Original manufacturing flaw that progressed or something to check
for before being certain just an isolated failure? if there was ,say, a
power surge/spikes or something could that cause a failure to that diode
and nothing else? Was it just coincidence there was a water leak , over
electrical equipment elsewhere in the house about the time of this failure.

John-Del April 13th 14 12:22 PM

SMPS failure query
 
On Sunday, April 13, 2014 6:51:40 AM UTC-4, N_Cook wrote:
In a Philips CDR755, year 2000. Working fine previous time of use and

then nothing at the next use. Turned out to be a 1N5406 size package

SB360 3amp 60V shottky diode gone short circuit on the LV side for the

5V rail. No other colateral damage (not tried recording a CD yet but

both decks play) , maybe a very slight discolouration on the anode end

of the diode, could equally be from time of encapsulation. After the Tx

, I would have said probability-wise. about the least likely item to

fail. Original manufacturing flaw that progressed or something to check

for before being certain just an isolated failure? if there was ,say, a

power surge/spikes or something could that cause a failure to that diode

and nothing else? Was it just coincidence there was a water leak , over

electrical equipment elsewhere in the house about the time of this failure.


Don't over think this. Shorted diode, replaced, worked... move on. I see this all the time. If your 5V is stable and the diode runs cool, most likely an isolated failure. If it blows another, then revisit.


N_Cook April 13th 14 12:56 PM

SMPS failure query
 
On 13/04/2014 12:22, John-Del wrote:
On Sunday, April 13, 2014 6:51:40 AM UTC-4, N_Cook wrote:
In a Philips CDR755, year 2000. Working fine previous time of use and

then nothing at the next use. Turned out to be a 1N5406 size package

SB360 3amp 60V shottky diode gone short circuit on the LV side for the

5V rail. No other colateral damage (not tried recording a CD yet but

both decks play) , maybe a very slight discolouration on the anode end

of the diode, could equally be from time of encapsulation. After the Tx

, I would have said probability-wise. about the least likely item to

fail. Original manufacturing flaw that progressed or something to check

for before being certain just an isolated failure? if there was ,say, a

power surge/spikes or something could that cause a failure to that diode

and nothing else? Was it just coincidence there was a water leak , over

electrical equipment elsewhere in the house about the time of this failure.


Don't over think this. Shorted diode, replaced, worked... move on. I see this all the time. If your 5V is stable and the diode runs cool, most likely an isolated failure. If it blows another, then revisit.


I just don't like the idea of coincidences. The roof leak poured over a
music system and filled up the tape deck, at least they junked that .
This was in another room but happened over the same week.

William Sommerwerck April 13th 14 01:37 PM

SMPS failure query
 
"N_Cook" wrote in message ...

I just don't like the idea of coincidences. The roof leak poured
over a music system and filled up the tape deck, at least they
junked that. This was in another room but happened over the
same week.


There's a logical fallacy, "Post hoc, ergo propter hoc".

The world is irrational, and there are lots of coincidences. Take John-Del's
advice, and let it rest for the time being.


[email protected] April 14th 14 01:17 AM

SMPS failure query
 
On Sunday, April 13, 2014 4:22:17 AM UTC-7, John-Del wrote:
On Sunday, April 13, 2014 6:51:40 AM UTC-4, N_Cook wrote:

In a Philips CDR755, year 2000. Working fine previous time of use and




then nothing at the next use. Turned out to be a 1N5406 size package




SB360 3amp 60V shottky diode gone short circuit on the LV side for the




5V rail. No other colateral damage (not tried recording a CD yet but




both decks play) , maybe a very slight discolouration on the anode end




of the diode, could equally be from time of encapsulation. After the Tx




, I would have said probability-wise. about the least likely item to




fail. Original manufacturing flaw that progressed or something to check




for before being certain just an isolated failure? if there was ,say, a




power surge/spikes or something could that cause a failure to that diode




and nothing else? Was it just coincidence there was a water leak , over




electrical equipment elsewhere in the house about the time of this failure.




Don't over think this. Shorted diode, replaced, worked... move on. I see this all the time. If your 5V is stable and the diode runs cool, most likely an isolated failure. If it blows another, then revisit.


14 years old? change the caps with low ESR units.



Arfa Daily April 23rd 14 01:40 AM

SMPS failure query
 


"N_Cook" wrote in message
...
In a Philips CDR755, year 2000. Working fine previous time of use and then
nothing at the next use. Turned out to be a 1N5406 size package SB360 3amp
60V shottky diode gone short circuit on the LV side for the 5V rail. No
other colateral damage (not tried recording a CD yet but both decks play)
,


Beware when attempting to record on one of these. Most if not all Philips CD
recorders need the disc that you are attempting to record on to be a
"CDR-Audio" type, which has an 'electronic watermark' to say that duty has
been paid. These are getting a bit rare to get hold of in shops now, but
still readily available online.

Arfa





N_Cook April 23rd 14 08:04 AM

SMPS failure query
 
On 23/04/2014 01:40, Arfa Daily wrote:


"N_Cook" wrote in message
...
In a Philips CDR755, year 2000. Working fine previous time of use and
then nothing at the next use. Turned out to be a 1N5406 size package
SB360 3amp 60V shottky diode gone short circuit on the LV side for the
5V rail. No other colateral damage (not tried recording a CD yet but
both decks play) ,


Beware when attempting to record on one of these. Most if not all
Philips CD recorders need the disc that you are attempting to record on
to be a "CDR-Audio" type, which has an 'electronic watermark' to say
that duty has been paid. These are getting a bit rare to get hold of in
shops now, but still readily available online.

Arfa





Yes, my checking out came to a halt at that statement. I'll have to ask
the owner, next time I see him, where he gets those 2010s blanks. All I
know is he has no difficulty in getting hold of 1920s jazz records