Alpha M footswitches, have a definite click action by finger feel and by sound, but only a momentary action. Is there a flavour of momentary switch that has a click effect for psychological feed back to the operator? SPDT, 2 have 2J4 and one 2J3 white stencilled on the switch body. 3 such in a piece of kit only 3 to 6 months old, but now only momentary. I'll break into one to check, but anyone come across momentary switches with click action? |
Do latching footswitches always click ?
"N_Cook" wrote in message ... If something quacks like a duck ... Alpha M footswitches, have a definite click action by finger feel and by sound, but only a momentary action. Is there a flavour of momentary switch that has a click effect for psychological feed back to the operator? SPDT, 2 have 2J4 and one 2J3 white stencilled on the switch body. 3 such in a piece of kit only 3 to 6 months old, but now only momentary. I'll break into one to check, but anyone come across momentary switches with click action? Marshall use them in some footswitch units. It is a soft click, unlike the latching ones, but a definite click. There are no manufacturers marks on these switches so I have no idea who makes them. Gareth. |
Do latching footswitches always click ?
On 08/04/2014 09:52, Gareth Magennis wrote:
"N_Cook" wrote in message ... If something quacks like a duck ... Alpha M footswitches, have a definite click action by finger feel and by sound, but only a momentary action. Is there a flavour of momentary switch that has a click effect for psychological feed back to the operator? SPDT, 2 have 2J4 and one 2J3 white stencilled on the switch body. 3 such in a piece of kit only 3 to 6 months old, but now only momentary. I'll break into one to check, but anyone come across momentary switches with click action? Marshall use them in some footswitch units. It is a soft click, unlike the latching ones, but a definite click. There are no manufacturers marks on these switches so I have no idea who makes them. Gareth. I'll look out for those, noticeably different feel to finger actuation compared to definite mechanical toggle switch action? Getting inside the problem one, it has all the innards of a conventional rocker switch put a pin plunger in the stem of the switch instead. No across-the-stem pin that is part of the mechanism and often bends as the failure mode on a lot of those latching ones. Looks like a design flaw and so generic fault with ALPHA M footswitches of 2012/2013 vintage. Assuming they are supposed to be latching and don't use all the rocking action as a psychological click generator. The contact holding rocker pivots over to make the opposite contact but then swings back. The stem of the sw bottoms out too early, because perhaps, the pin that is axial to the sprung actuator stem and engages in the rocker , and bends a bit to follow the 2 rocker positions, is too sharp and must dig into the PPE plastic of the rocker assembly over a few hundred actuations. I suspect they've done away with a tiny metal cup seated in the rocker recess, to receive this pin. |
Do latching footswitches always click ?
I reversed the contact bar and same non-latching the other way. Did not
think to try reversing the rocker assembly and trying the non-worn? recess and have moved on to other repair work now, as had not thought through what the underlying problem must be, at that point. |
Do latching footswitches always click ?
"N_Cook" wrote in message ... On 08/04/2014 09:52, Gareth Magennis wrote: "N_Cook" wrote in message ... If something quacks like a duck ... Alpha M footswitches, have a definite click action by finger feel and by sound, but only a momentary action. Is there a flavour of momentary switch that has a click effect for psychological feed back to the operator? SPDT, 2 have 2J4 and one 2J3 white stencilled on the switch body. 3 such in a piece of kit only 3 to 6 months old, but now only momentary. I'll break into one to check, but anyone come across momentary switches with click action? Marshall use them in some footswitch units. It is a soft click, unlike the latching ones, but a definite click. There are no manufacturers marks on these switches so I have no idea who makes them. Gareth. I'll look out for those, noticeably different feel to finger actuation compared to definite mechanical toggle switch action? Yes, more of a heavy duty tactile switch type operation. Gareth. |
Do latching footswitches always click ?
On Tuesday, April 8, 2014 4:45:39 AM UTC-4, N_Cook wrote:
If something quacks like a duck ... Alpha M footswitches, have a definite click action by finger feel and by sound, but only a momentary action. Is there a flavour of momentary switch that has a click effect for psychological feed back to the operator? SPDT, 2 have 2J4 and one 2J3 white stencilled on the switch body. 3 such in a piece of kit only 3 to 6 months old, but now only momentary. I'll break into one to check, but anyone come across momentary switches with click action? I put in an alarm system years ago and installed one of those type switches under a desk. We used to call them "kick bars". If you're looking for a silent operation then perhaps a company that sells alarm equipment might be a good source. Most modern alarm systems require only momentary contact to initiate an alarm though. Lenny |
Do latching footswitches always click ?
I stocked up with momentary and latching footswitches. Pure coincidence
, the momentary ones are ALPHA M, stencilled 3N1 and are DPDT. But the feel is exactly as the suspect one. So as the original was packed full of grease then perhaps just dodgey contact and then no latency in the electronics, 300mS or so. So far all I know is 200 ohm, triggers sw action and 27K does not. I think 100nF+100K will go across the contact and see if it still works and also whether manually shorting across, 1/10 second or so spacing, still de-latches. If its dodgey contacts combined with no latency then replacing with latching or momentary will not make any difference , in time, as the contact cleanness fails. Then the (design) fault will return, unless slowing down the electronics. This is going to be a generic fault with these stomp boxes , Vocalist Live 3, Harman Music, designed in Canada on the overlay |
Do latching footswitches always click ?
ALPHA M momentary can be converted to latching by just flattening out
the hump on one side ,in the rocking arm with the contacts at either end. Nothing do do with a sharp pin and a failing latching type switch. So in answer to the title, both momentary and latching types can click |