I was using my t-912 for about an hour, then I walked away and came
back, there was no trace anymore. The crt filament lights up fine, and I can see the trace briefly appear then I turn off the power switch, so for some reason it is being blanked, I guess. The beam finder does not help finding the beam. Not having a schematic I don't know what voltages to check for at the various test points. If anyone has any suggestions, or a schematic, please let me know. |
#3
![]() |
|||
|
|||
![]()
Is anyone can scan and emal me the shematic for the power supply
board, I would appreciate it greatly. Jim Yanik wrote in message ... (whipaway) wrote in om: I was using my t-912 for about an hour, then I walked away and came back, there was no trace anymore. The crt filament lights up fine, and I can see the trace briefly appear then I turn off the power switch, so for some reason it is being blanked, I guess. The beam finder does not help finding the beam. Not having a schematic I don't know what voltages to check for at the various test points. If anyone has any suggestions, or a schematic, please let me know. Ebay or www.big-list for a service manual,or http://www.logwell.com/tech/oscilloscopes/manuals.html |
#4
![]() |
|||
|
|||
![]()
(whipaway) wrote in
om: I checked the Power supply PCB and there is 13v on the 120V output, i checked all of the components on the PCB everything is OK, maybe xfrmr is bad? I don't have a schematic either,so I can't answer this. There may be a small fuse on a small PCB on the xfmr. Jim Yanik wrote in message ... (whipaway) wrote in om: I was using my t-912 for about an hour, then I walked away and came back, there was no trace anymore. The crt filament lights up fine, and I can see the trace briefly appear then I turn off the power switch, so for some reason it is being blanked, I guess. The beam finder does not help finding the beam. Not having a schematic I don't know what voltages to check for at the various test points. If anyone has any suggestions, or a schematic, please let me know. Ebay or www.big-list for a service manual,or http://www.logwell.com/tech/oscilloscopes/manuals.html -- Jim Yanik,NRA member remove null to contact me |
#5
![]() |
|||
|
|||
![]()
C478 had become shorted. Replacing it with .033uF @ 400V cured the problem.
(whipaway) wrote in message . com... I was using my t-912 for about an hour, then I walked away and came back, there was no trace anymore. The crt filament lights up fine, and I can see the trace briefly appear then I turn off the power switch, so for some reason it is being blanked, I guess. The beam finder does not help finding the beam. Not having a schematic I don't know what voltages to check for at the various test points. If anyone has any suggestions, or a schematic, please let me know. |