Hi,
My HRD has developed a fault and I'm pretty good with electronics, safety (discharging caps etc) and soldering, but I don't have the circuit knowledge to work out which components are faulty. Could someone here offer any help please ? The symptoms are that it's making a horrible buzz on the 'drive' & 'more drive' channels, as well as letting some sound through on the clean channel when the volume is at zero. Here's the full schematic.... http://www.fender.com/support/amp_sc..._Schematic.pdf And here's just the preamp section: http://studentweb.eku.edu/justin_hol...HRDxpreamp.gif Here's a Wav file of the noise it's making... http://www.fileden.com/files/2006/6/...9/Amp_Buzz.wav Be careful when listening to it, it starts off very quietly then gradually gets loud - so don't turn up your speakers because you can't hear it very well when it starts ! The increase in oscillation frequency is caused by me turning the DRIVE knob from 12 down to 0. Turning the BASS knob from 12 to 0 also has a similar effect. Adjusting any of the other controls does not cause a change in frequency - only in volume / tone of the buzz. This is happening *only* on the Drive channel, and gets nastier with the MORE DRIVE button pushed. The recording was done with nothing plugged into the amp. With the amp on the clean channel, you can hear a little output from the speaker with the VOLUME set to zero - which it never used to do. Apart from this anomaly, the amp behaves fine on the clean channel and I used it for practice this week. I've tried swapping positions of the preamp valves and also a different set of power amp valves - no difference. I've also tried resoldering R78 & R79, which apparently have a tendency to develop dry joints, and all the big electrolytic caps. I'm more than happy to give test point readings to anyone who can help... the schematic gives TP voltages so hopefully that might be of use. Anyone ? Many thanks in advance - I really can't afford to take this anywhere to be repaired. |
#2
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
wrote in message
... Hi, My HRD has developed a fault and I'm pretty good with electronics, safety (discharging caps etc) and soldering, but I don't have the circuit knowledge to work out which components are faulty. Could someone here offer any help please ? The symptoms are that it's making a horrible buzz on the 'drive' & 'more drive' channels, as well as letting some sound through on the clean channel when the volume is at zero. Here's the full schematic.... http://www.fender.com/support/amp_sc...xe_Schematic.p df And here's just the preamp section: http://studentweb.eku.edu/justin_hol...HRDxpreamp.gif Here's a Wav file of the noise it's making... http://www.fileden.com/files/2006/6/...9/Amp_Buzz.wav Be careful when listening to it, it starts off very quietly then gradually gets loud - so don't turn up your speakers because you can't hear it very well when it starts ! The increase in oscillation frequency is caused by me turning the DRIVE knob from 12 down to 0. Turning the BASS knob from 12 to 0 also has a similar effect. Adjusting any of the other controls does not cause a change in frequency - only in volume / tone of the buzz. This is happening *only* on the Drive channel, and gets nastier with the MORE DRIVE button pushed. The recording was done with nothing plugged into the amp. With the amp on the clean channel, you can hear a little output from the speaker with the VOLUME set to zero - which it never used to do. Apart from this anomaly, the amp behaves fine on the clean channel and I used it for practice this week. I've tried swapping positions of the preamp valves and also a different set of power amp valves - no difference. I've also tried resoldering R78 & R79, which apparently have a tendency to develop dry joints, and all the big electrolytic caps. I'm more than happy to give test point readings to anyone who can help... the schematic gives TP voltages so hopefully that might be of use. Anyone ? Many thanks in advance - I really can't afford to take this anywhere to be repaired. buzz at mains frequency F , 2*F or 3*F ? or random -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#3
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
wrote in message
... Hi, My HRD has developed a fault and I'm pretty good with electronics, safety (discharging caps etc) and soldering, but I don't have the circuit knowledge to work out which components are faulty. Could someone here offer any help please ? The symptoms are that it's making a horrible buzz on the 'drive' & 'more drive' channels, as well as letting some sound through on the clean channel when the volume is at zero. Here's the full schematic.... http://www.fender.com/support/amp_sc...xe_Schematic.p df And here's just the preamp section: http://studentweb.eku.edu/justin_hol...HRDxpreamp.gif Here's a Wav file of the noise it's making... http://www.fileden.com/files/2006/6/...9/Amp_Buzz.wav Be careful when listening to it, it starts off very quietly then gradually gets loud - so don't turn up your speakers because you can't hear it very well when it starts ! The increase in oscillation frequency is caused by me turning the DRIVE knob from 12 down to 0. Turning the BASS knob from 12 to 0 also has a similar effect. Adjusting any of the other controls does not cause a change in frequency - only in volume / tone of the buzz. This is happening *only* on the Drive channel, and gets nastier with the MORE DRIVE button pushed. The recording was done with nothing plugged into the amp. With the amp on the clean channel, you can hear a little output from the speaker with the VOLUME set to zero - which it never used to do. Apart from this anomaly, the amp behaves fine on the clean channel and I used it for practice this week. I've tried swapping positions of the preamp valves and also a different set of power amp valves - no difference. I've also tried resoldering R78 & R79, which apparently have a tendency to develop dry joints, and all the big electrolytic caps. I'm more than happy to give test point readings to anyone who can help... the schematic gives TP voltages so hopefully that might be of use. Anyone ? Many thanks in advance - I really can't afford to take this anywhere to be repaired. I would try touching a grounded 1nF, HV cap to various points until a change of oscillation frequency and then change whatever gives the gain in that part of the circuit. I only read down to wav file ref before, sound card in my other pc -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#4
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]() "N_Cook" wrote in message ... wrote in message ... Hi, My HRD has developed a fault and I'm pretty good with electronics, safety (discharging caps etc) and soldering, but I don't have the circuit knowledge to work out which components are faulty. Could someone here offer any help please ? The symptoms are that it's making a horrible buzz on the 'drive' & 'more drive' channels, as well as letting some sound through on the clean channel when the volume is at zero. Here's the full schematic.... http://www.fender.com/support/amp_sc...xe_Schematic.p df And here's just the preamp section: http://studentweb.eku.edu/justin_hol...HRDxpreamp.gif Here's a Wav file of the noise it's making... http://www.fileden.com/files/2006/6/...9/Amp_Buzz.wav Be careful when listening to it, it starts off very quietly then gradually gets loud - so don't turn up your speakers because you can't hear it very well when it starts ! The increase in oscillation frequency is caused by me turning the DRIVE knob from 12 down to 0. Turning the BASS knob from 12 to 0 also has a similar effect. Adjusting any of the other controls does not cause a change in frequency - only in volume / tone of the buzz. This is happening *only* on the Drive channel, and gets nastier with the MORE DRIVE button pushed. The recording was done with nothing plugged into the amp. With the amp on the clean channel, you can hear a little output from the speaker with the VOLUME set to zero - which it never used to do. Apart from this anomaly, the amp behaves fine on the clean channel and I used it for practice this week. I've tried swapping positions of the preamp valves and also a different set of power amp valves - no difference. I've also tried resoldering R78 & R79, which apparently have a tendency to develop dry joints, and all the big electrolytic caps. I'm more than happy to give test point readings to anyone who can help... the schematic gives TP voltages so hopefully that might be of use. Anyone ? Many thanks in advance - I really can't afford to take this anywhere to be repaired. I would try touching a grounded 1nF, HV cap to various points until a change of oscillation frequency and then change whatever gives the gain in that part of the circuit. I only read down to wav file ref before, sound card in my other pc -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ Trust me - I tried all of that to no avail. The problem is in the preamp section, around the opamps somewhere, but no amount of additional decoupling or alteration in the gains of the relevant stages, made any appreciable difference to the problem. I checked every component in the area, both visually, and electrically. I did at one point find a resistor which was not the value that it stated on the schematics, but changing it to the correct (?) value, again made no difference to the problem, which I kind of expected would be the case anyway, as the amp had apparently worked correctly before developing this problem. Arfa |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Valve Amplifier fault - nasty buzz. | Electronics Repair | |||
Valve,Butterfly valve,Globe valve,Check valve,Ball valve,Plug valve,Marine valve,Gate valve,Flow control valve | UK diy | |||
Valve,butterfly valve,ball valve,check valve,globe valve | Home Repair | |||
solenoid valve buzz | Home Repair | |||
fault finding on CH roomstat or 3 way mid positin valve | UK diy |