How is it possible to turn on a Compaq PS-6301-1 on the bench?
PS-6301-1 is a hot-plug switching power supply for Compaq servers.
I have the backplane connector pin-out (see above). A while after turn-on pin23 (READY) goes up to +5V. Grounding pin 25 (PSON) all outputs go up but fall immediately down to zero and pin 23 (READY) goes low; it remains low for 4-5 seconds and the goes back to high. Even shorting remote sensing pins to their respective outputs (46with42 and 64with66) nothing changes. Something is still missing. Does anybody out there know what is it? What are "Interlock", "Installed" and "Hard Boot" pins useful for? Are they involved? THX in advance. IW1DHI - Emanuele. === Backplane connector Pin-out : 3V3 69 70 3V3 3V3 67 68 3V3 3V3 65 66 3V3 3V3 S- 63 64 3V3 S+ (Remote Sense) 5VAUX 61 62 N/C RTN 59 60 RTN RTN 57 58 RTN RTN 55 56 RTN RTN 53 54 RTN RTN 51 52 RTN RTN 49 50 RTN RTN 47 48 RTN 5V S- 45 46 5V S+ (remote sense) 5V 43 44 N/C 5V 41 42 5V 5V 39 40 5V 5V 37 38 5V -12V 35 36 -5V 12V 33 34 12V 12V 31 32 12V 12V 29 30 N/C Installed 27 28 N/C On/Stby 25 26 Interlock Ready4Start 23 24 Hard Boot Power Good 21 22 N/C N/C 19 20 N/C N/C 17 18 N/C RTN 15 16 RTN RTN 13 14 RTN RTN 11 12 RTN RTN 09 10 RTN N/C 07 08 N/C N/C 05 06 N/C N/C 03 04 N/C N/C 01 02 N/C |
#2
Posted to sci.electronics.repair
|
|||
|
|||
How is it possible to turn on a Compaq PS-6301-1 on the bench?
On 5 Lug, 00:26, Emanuele Girlando
wrote: PS-6301-1 is a hot-plug switching power supply for Compaq servers. I have the backplane connector pin-out (see above). A while after turn-on pin23 (READY) goes up to +5V. Grounding pin 25 (PSON) all outputs go up but fall immediately down to zero and pin 23 (READY) goes low; it remains low for 4-5 seconds and the goes back to high. Even shorting remote sensing pins to their respective outputs (46with42 and 64with66) nothing changes. Something is still missing. Does anybody out there know what is it? What are "Interlock", "Installed" and "Hard Boot" pins useful for? Are they involved? THX in advance. IW1DHI - Emanuele. === Backplane connector Pin-out : 3V3 69 70 3V3 3V3 67 68 3V3 3V3 65 66 3V3 3V3 S- 63 64 3V3 S+ (Remote Sense) 5VAUX 61 62 N/C RTN 59 60 RTN RTN 57 58 RTN RTN 55 56 RTN RTN 53 54 RTN RTN 51 52 RTN RTN 49 50 RTN RTN 47 48 RTN 5V S- 45 46 5V S+ (remote sense) 5V 43 44 N/C 5V 41 42 5V 5V 39 40 5V 5V 37 38 5V -12V 35 36 -5V 12V 33 34 12V 12V 31 32 12V 12V 29 30 N/C Installed 27 28 N/C On/Stby 25 26 Interlock Ready4Start 23 24 Hard Boot Power Good 21 22 N/C N/C 19 20 N/C N/C 17 18 N/C RTN 15 16 RTN RTN 13 14 RTN RTN 11 12 RTN RTN 09 10 RTN N/C 07 08 N/C N/C 05 06 N/C N/C 03 04 N/C N/C 01 02 N/C An update: connecting a 12V lamp to the +5V output din't solve the problem. I 've got a single weak flash. |
#3
Posted to sci.electronics.repair
|
|||
|
|||
How is it possible to turn on a Compaq PS-6301-1 on the bench?
On 5 Lug, 16:28, Emanuele Girlando
wrote: On 5 Lug, 00:26, Emanuele Girlando wrote: PS-6301-1is a hot-plug switching power supply for Compaq servers. I have the backplane connector pin-out (see above). A while after turn-on pin23 (READY) goes up to +5V. Grounding pin 25 (PSON) all outputs go up but fall immediately down to zero and pin 23 (READY) goes low; it remains low for 4-5 seconds and the goes back to high. Even shorting remote sensing pins to their respective outputs (46with42 and 64with66) nothing changes. Something is still missing. Does anybody out there know what is it? What are "Interlock", "Installed" and "Hard Boot" pins useful for? Are they involved? THX in advance. IW1DHI - Emanuele. === Backplane connector Pin-out : 3V3 69 70 3V3 3V3 67 68 3V3 3V3 65 66 3V3 3V3 S- 63 64 3V3 S+ (Remote Sense) 5VAUX 61 62 N/C RTN 59 60 RTN RTN 57 58 RTN RTN 55 56 RTN RTN 53 54 RTN RTN 51 52 RTN RTN 49 50 RTN RTN 47 48 RTN 5V S- 45 46 5V S+ (remote sense) 5V 43 44 N/C 5V 41 42 5V 5V 39 40 5V 5V 37 38 5V -12V 35 36 -5V 12V 33 34 12V 12V 31 32 12V 12V 29 30 N/C Installed 27 28 N/C On/Stby 25 26 Interlock Ready4Start 23 24 Hard Boot Power Good 21 22 N/C N/C 19 20 N/C N/C 17 18 N/C RTN 15 16 RTN RTN 13 14 RTN RTN 11 12 RTN RTN 09 10 RTN N/C 07 08 N/C N/C 05 06 N/C N/C 03 04 N/C N/C 01 02 N/C An update: connecting a 12V lamp to the +5V output din't solve the problem. I 've got a single weak flash. GOT it! The interlock pin has to be connected to GND. It works even with no load on any output. So, to summarise the connections needed: All "remote sense" pins to the corresponding outputs and GND: 46with42, 45with 47, 64with66, 63with59 Interlock to GND: 26with16 Then connecting 25with any GND the PSU fires up. Bingo. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Wood prepped for second half of bench top - Bitsa Bench | Woodworking Plans and Photos | |||
compaq presario wont turn on... | Electronics Repair | |||
compaq laptop 12XL125 does not turn on | Electronics Repair | |||
Every turn your bench grinder on its end? | Woodworking | |||
Sony Model KV-32XBR48 slow turn on and flashing video for short period at turn on | Electronics Repair |