Home |
Search |
Today's Posts |
![]() |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
![]()
Posted to sci.electronics.design,sci.electronics.repair
|
|||
|
|||
![]()
http://home.graffiti.net/diverse:graffiti.net/prot.jpg
The thermal switch monitors the heatsink but what is the function of the depletion type FET, monitoring the negative half cycle of the the AC3 ac line, via D3 ? What happens in a fault mode to that line that can be monitored and could be of use for protection.operation? What does D1 do ? The relay contact cuts in serious attenuation of the signal going to the pa in fault mode -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#2
![]()
Posted to sci.electronics.design,sci.electronics.repair
|
|||
|
|||
![]() "N Cook" http://home.graffiti.net/diverse:graffiti.net/prot.jpg The thermal switch monitors the heatsink but what is the function of the depletion type FET, monitoring the negative half cycle of the the AC3 ac line, via D3 ? ** Switch on delay - then un-mute the loudspeaker. AKA an anti * THUMP * circuit. What happens in a fault mode to that line that can be monitored and could be of use for protection.operation? ** Only if FS1 blows. What does D1 do ? ** Fast discharge of C5 - so a quick off for the relay when AC supply removed. Another anti-thump function. The relay contact cuts in serious attenuation of the signal going to the pa in fault mode ** There is no fault protection in that schem. ....... Phil -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#3
![]()
Posted to sci.electronics.design,sci.electronics.repair
|
|||
|
|||
![]()
Phil Allison wrote in message
... "N Cook" http://home.graffiti.net/diverse:graffiti.net/prot.jpg The thermal switch monitors the heatsink but what is the function of the depletion type FET, monitoring the negative half cycle of the the AC3 ac line, via D3 ? ** Switch on delay - then un-mute the loudspeaker. AKA an anti * THUMP * circuit. What happens in a fault mode to that line that can be monitored and could be of use for protection.operation? ** Only if FS1 blows. What does D1 do ? ** Fast discharge of C5 - so a quick off for the relay when AC supply removed. Another anti-thump function. The relay contact cuts in serious attenuation of the signal going to the pa in fault mode ** There is no fault protection in that schem. ...... Phil -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ So obvious when you point it out, I only assumed it was overload protection and never thought of a mute function. The problem with the amp itself, the relay was falsely cutting in and dropping the gain plus distortion of the pa in normal use. Presumably one of the Cs or the FET playing up, will be looking at it later today. -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#4
![]()
Posted to sci.electronics.design,sci.electronics.repair
|
|||
|
|||
![]() N Cook wrote: http://home.graffiti.net/diverse:graffiti.net/prot.jpg The thermal switch monitors the heatsink but what is the function of the depletion type FET, monitoring the negative half cycle of the the AC3 ac line, via D3 ? What happens in a fault mode to that line that can be monitored and could be of use for protection.operation? What does D1 do ? The relay contact cuts in serious attenuation of the signal going to the pa in fault mode For starters it's not a 'depletion type FET'. It's a plain old JFET (junction fet). JFETs are on with zero gate volts so it conducts when AC is not present holding the relay off by diverting base current from TR10. When AC is present, it turns off due to the negative gate voltage - energising the relay. Graham |
#5
![]()
Posted to sci.electronics.design,sci.electronics.repair
|
|||
|
|||
![]()
Eeyore wrote in message
... N Cook wrote: http://home.graffiti.net/diverse:graffiti.net/prot.jpg The thermal switch monitors the heatsink but what is the function of the depletion type FET, monitoring the negative half cycle of the the AC3 ac line, via D3 ? What happens in a fault mode to that line that can be monitored and could be of use for protection.operation? What does D1 do ? The relay contact cuts in serious attenuation of the signal going to the pa in fault mode For starters it's not a 'depletion type FET'. It's a plain old JFET (junction fet). JFETs are on with zero gate volts so it conducts when AC is not present holding the relay off by diverting base current from TR10. When AC is present, it turns off due to the negative gate voltage - energising the relay. Graham I should retain this J112 as a collecor's item then. Circuit operates with the relay energised in normal audio operation , after power-on hold-off, relay contacts are o/c in audio use -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Very Odd Audio Common Mode Condition Started Just Before Midnight 12/31--Audio Feedback Oscillation through Power Line? | Electronics | |||
LA4145 audio power integrated circuit source help request | Electronics Repair | |||
Audio amplifier thermal protection | Electronics Repair | |||
Need circuit (or device) to detect audio pre-amp and switch AC power when a signal is present | Electronics | |||
Question about static shock protection of audio/video inputs | Electronics Repair |