What I;m doing now is doing test of a rf signal generator.
When I turned it on, it showed Uncal warning and generated no rf signal. Meaning of error code was that PLL is unlocked. I'm ,however, newcomer to RF generator world. .. What does "PLL unlocked " means for RF signal generator. The model I'm doing test is fluek 6060 B |
#2
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
Unlocked PLL norrmally means the Phase Lock Loop device is free running,
that the control datum, or parametres are either out of range or are incorrect for that particular item. Suggest referring to the operations manual for the Fluke generator you are attempting to use. Check the operating frequencies the item will actually output and the 'mode du emploe' it's specific function. "sperelat" wrote in message oups.com... What I;m doing now is doing test of a rf signal generator. When I turned it on, it showed Uncal warning and generated no rf signal. Meaning of error code was that PLL is unlocked. I'm ,however, newcomer to RF generator world. .. What does "PLL unlocked " means for RF signal generator. The model I'm doing test is fluek 6060 B |
#3
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
On Sep 12, 9:37 am, sperelat wrote:
What I;m doing now is doing test of a rf signal generator. When I turned it on, it showed Uncal warning and generated no rf signal. Meaning of error code was that PLL is unlocked. I'm ,however, newcomer to RF generator world. .. What does "PLL unlocked " means for RF signal generator. The model I'm doing test is fluek 6060 B Next to the RF output connector, there is an RF Output On/Off button. Push it to turn on the output. The "Uncal" indicator should go out. The "Uncal" indicator normally comes on when the RF Output is turned Off. IIRC, the 6060B powers up in the RF Off, "Uncal" state. Also make sure the Freq. REF switch on the rear panel is set to "INT", unless you're using an external frequnecy standard. Mike WB2MEP |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
FA: RF Signal Generator AN/URM-25 HF AM modulation only | Electronics Repair | |||
signal generator to frequency counter signal tap | Electronics | |||
signal generator | Home Repair | |||
B&K E-200D signal generator - no signal | Electronics Repair | |||
FS Percision Generator Signal E-200-C | Home Repair |