I have just recently aquired a Gould OS1200 oscilloscope. Basically it works fine except that the Sweep trace compresses up on the right hand side of the when I set the timebase to 5uS and up. I have measured most test points on the Horizontal timebase PCB and cannot find anything unusual. Please the following example pictures showing the compresses trace. Also have photos showing the Sawtooth ramp generator and ramp output if this helps. http://picasaweb.google.co.uk/ivanr0...illoscopeTrace I am really looking for some guidance on where I should be checking. Regards Ivan |
#2
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
wrote in message
ups.com... (Sorry forgot the link to photos on previous message) I have just recently aquired a Gould OS1200 oscilloscope. Basically it works fine except that the Sweep trace compresses up on the right hand side of the when I set the timebase to 5uS and up. I have measured most test points on the Horizontal timebase PCB and cannot find anything unusual. Please the following example pictures showing the compresses trace. Also have photos showing the Sawtooth ramp generator and ramp output if this helps. http://picasaweb.google.co.uk/ivanr0...illoscopeTrace I am really looking for some guidance on where I should be checking. Regards Ivan check/replace the X plate driver trannies, one is probably wonky -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list on http://home.graffiti.net/diverse:graffiti.net/ |
#3
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
On Mar 30, 10:22 am, "N Cook" wrote:
wrote in message ups.com... (Sorry forgot the link to photos on previous message) I have just recently aquired a Gould OS1200 oscilloscope. Basically it works fine except that the Sweep trace compresses up on the right hand side of the when I set the timebase to 5uS and up. I have measured most test points on the Horizontal timebase PCB and cannot find anything unusual. Please the following example pictures showing the compresses trace. Also have photos showing the Sawtooth ramp generator and ramp output if this helps. http://picasaweb.google.co.uk/ivanr0...illoscopeTrace I am really looking for some guidance on where I should be checking. Regards Ivan check/replace the X plate driver trannies, one is probably wonky -- Diverse Devices, Southampton, England electronic hints and repair briefs , schematics/manuals list onhttp://home.graffiti.net/diverse:graffiti.net/- Hide quoted text - - Show quoted text - Have checked them and they seem OK allthough the voltage on the plates are a bit low. I have had sugestions that the problem may lay in the timing of the Hold off/blanking circuit. Regards Ivan |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Gould Oscilloscope OS1200 Sweep compression | Electronics Repair | |||
Gould 450 Oscilloscope | Electronics Repair | |||
Schematics for Oscilloscope Gould (DSO) 420 | Electronics Repair | |||
Advance Gould OS1000A Oscilloscope | Electronics Repair | |||
Advance Gould OS1000A Oscilloscope | Electronics |