Home |
Search |
Today's Posts |
![]() |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
Hi, might remember I have this Hitachi 51SWX20B chassis DP27, Aug
2002. Bear with me, it's very frustrating and owner is nagging. Kip, you might want to see the images. Also to Kip and others, if you still want to send info or your experiences, let me know with and for Kip, please tell me how big the files are. jpero @ sympatico . ca (remove spaces). Here's two links of pictures of this green vertical lines noise, 22K close up and 33K area in general respectively: http://www3.sympatico.ca/jpero/greenmoving.jpg http://www3.sympatico.ca/jpero/fullgreenmoving.jpg These two pictures, ignore the misconvergence, this is not the issue since I have already replaced the generator module. The green only moved from it's usual position to the right with this fainter vertical line in erratic way and very intermittently comes together back to normal with "ghost lines & vertical green misconvergence" disappeared for awhile. Then problem reappears, diappears erratically can take hours in span. And it does intermittently moves like a jitter with that faint noise ahead more farther or less in sync with the main green vertical lines displacement. Move to right, the fainter noise is more farther it is. More to the right into convergence with the R and B, fainter lines less apart, sometimes disappears. It is the green only since did blinded the blue, red and green with a len cap to make sure. This seems to make me think the green somehow is "delayed" with noise added to it. What I have done: replaced convergence generator module, TA1360N (I401), checked electrolytic capacitors, measured ohms. including three CRT boards (dealing with metal shield is a pain but easily done). Heat & cold, tapping, flexing treatments does not affect this. I would be really very surprised if that is really the convergence ICs, oh yes, unplugged all VM coils to no effect. Also, is there a way to SEE the noise on scope like that? I have hard time looking for the "noise" in sea of video waveforms. Cheers, Wizard |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
ATTN: Kip Hitachi 51SWX20B tough convergence issue | Electronics Repair | |||
Attn: Kip: update and Intermittent convergence problem on Hitachi 51SWX20B | Electronics Repair | |||
Attn: Kip: Intermittent convergence problem on Hitachi 51SWX20B | Electronics Repair | |||
Intermittent convergence problem on Hitachi 51SWX20B | Electronics Repair | |||
hitachi 51SWX20B intermittent minor convergence pulling apart. | Electronics Repair |