Hi, might remember I have this Hitachi 51SWX20B chassis DP27, Aug
2002. Bear with me, it's very frustrating and owner is nagging. Kip,
you might want to see the images. Also to Kip and others, if you
still want to send info or your experiences, let me know with and for
Kip, please tell me how big the files are.

jpero @ sympatico . ca (remove spaces).

Here's two links of pictures of this green vertical lines noise, 22K
close up and 33K area in general respectively:

http://www3.sympatico.ca/jpero/greenmoving.jpg

http://www3.sympatico.ca/jpero/fullgreenmoving.jpg

These two pictures, ignore the misconvergence, this is not the issue
since I have already replaced the generator module. The green only
moved from it's usual position to the right with this fainter vertical
line in erratic way and very intermittently comes together back to
normal with "ghost lines & vertical green misconvergence" disappeared
for awhile. Then problem reappears, diappears erratically can take
hours in span. And it does intermittently moves like a jitter with
that faint noise ahead more farther or less in sync with the main
green vertical lines displacement. Move to right, the fainter noise
is more farther it is. More to the right into convergence with the R
and B, fainter lines less apart, sometimes disappears.

It is the green only since did blinded the blue, red and green with a
len cap to make sure. This seems to make me think the green somehow
is "delayed" with noise added to it.

What I have done: replaced convergence generator module, TA1360N
(I401), checked electrolytic capacitors, measured ohms. including
three CRT boards (dealing with metal shield is a pain but easily
done).
Heat & cold, tapping, flexing treatments does not affect this. I
would be really very surprised if that is really the convergence ICs,
oh yes, unplugged all VM coils to no effect.

Also, is there a way to SEE the noise on scope like that? I have hard
time looking for the "noise" in sea of video waveforms.

Cheers, Wizard
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
ATTN: Kip Hitachi 51SWX20B tough convergence issue Jason D. Electronics Repair 0 January 30th 07 08:10 PM
Attn: Kip: update and Intermittent convergence problem on Hitachi 51SWX20B Jason D. Electronics Repair 0 January 26th 07 03:13 PM
Attn: Kip: Intermittent convergence problem on Hitachi 51SWX20B Jason D. Electronics Repair 0 January 23rd 07 06:48 PM
Intermittent convergence problem on Hitachi 51SWX20B Jason D. Electronics Repair 3 January 22nd 07 02:52 PM
hitachi 51SWX20B intermittent minor convergence pulling apart. Jason D. Electronics Repair 1 November 22nd 06 11:15 AM


All times are GMT +1. The time now is 06:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"