Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 28
Default Testing two TO220 recifiers...

Hi,

I'm trying to repair an ATX power supply that has been dying a slow
death, turning the power switch on the back off/on has allowed the
computer to boot up for a couple of months but the supply finally died.

Shorting the two power wires on the bulk connector that normally make
the supply come on just make the supply give a little "Ziiiiiit" noise
then a very faint high frequency squeal can be heard.

I pulled the heat sink with the three transistors (two transistors and a
MOSFET) all three tested fine. I then pulled the heat sink with the
three rectifiers, one tested in the normal range but the other two were
testing at 0.99x and 0.2xx, I would normally expect these to be in the
0.4xx or 0.5xx, sometimes a low 0.6xx, is this normal?

The two rectifiers in question a SB1040 and SB1640.

Any help would be appreciated.


-Landon
  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 28
Default Testing two TO220 rectifiers...

lj_robins wrote:
Hi,

I'm trying to repair an ATX power supply that has been dying a slow
death, turning the power switch on the back off/on has allowed the
computer to boot up for a couple of months but the supply finally died.

Shorting the two power wires on the bulk connector that normally make
the supply come on just make the supply give a little "Ziiiiiit" noise
then a very faint high frequency squeal can be heard.

I pulled the heat sink with the three transistors (two transistors and a
MOSFET) all three tested fine. I then pulled the heat sink with the
three rectifiers, one tested in the normal range but the other two were
testing at 0.99x and 0.2xx, I would normally expect these to be in the
0.4xx or 0.5xx, sometimes a low 0.6xx, is this normal?

The two rectifiers in question a SB1040 and SB1640.

Any help would be appreciated.


-Landon


Hi again,

Sorry about the typo...

Here is what they are reading with the DMM on diode tester:

(negative lead on center pin)

SB1040: 0.201 on both outer pins.

SB1640: 0.169 on left outer pin, 0.170 on outer right pin.

(positive lead on center pin) all readings are infinity.



-Landon
  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Testing two TO220 rectifiers...

lj_robins wrote:
lj_robins wrote:

Hi,

I'm trying to repair an ATX power supply that has been dying a slow
death, turning the power switch on the back off/on has allowed the
computer to boot up for a couple of months but the supply finally died.

Shorting the two power wires on the bulk connector that normally make
the supply come on just make the supply give a little "Ziiiiiit" noise
then a very faint high frequency squeal can be heard.

I pulled the heat sink with the three transistors (two transistors and
a MOSFET) all three tested fine. I then pulled the heat sink with the
three rectifiers, one tested in the normal range but the other two
were testing at 0.99x and 0.2xx, I would normally expect these to be
in the 0.4xx or 0.5xx, sometimes a low 0.6xx, is this normal?

The two rectifiers in question a SB1040 and SB1640.

Any help would be appreciated.


-Landon



Hi again,

Sorry about the typo...

Here is what they are reading with the DMM on diode tester:

(negative lead on center pin)

SB1040: 0.201 on both outer pins.

SB1640: 0.169 on left outer pin, 0.170 on outer right pin.

(positive lead on center pin) all readings are infinity.



-Landon



Sounds like they're working fine.
  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 6,772
Default Testing two TO220 rectifiers...


"James Sweet" wrote in message
news:4c5fh.1185$A05.161@trndny08...
lj_robins wrote:
lj_robins wrote:

Hi,

I'm trying to repair an ATX power supply that has been dying a slow
death, turning the power switch on the back off/on has allowed the
computer to boot up for a couple of months but the supply finally died.

Shorting the two power wires on the bulk connector that normally make
the supply come on just make the supply give a little "Ziiiiiit" noise
then a very faint high frequency squeal can be heard.

I pulled the heat sink with the three transistors (two transistors and a
MOSFET) all three tested fine. I then pulled the heat sink with the
three rectifiers, one tested in the normal range but the other two were
testing at 0.99x and 0.2xx, I would normally expect these to be in the
0.4xx or 0.5xx, sometimes a low 0.6xx, is this normal?

The two rectifiers in question a SB1040 and SB1640.

Any help would be appreciated.


-Landon



Hi again,

Sorry about the typo...

Here is what they are reading with the DMM on diode tester:

(negative lead on center pin)

SB1040: 0.201 on both outer pins.

SB1640: 0.169 on left outer pin, 0.170 on outer right pin.

(positive lead on center pin) all readings are infinity.



-Landon



Sounds like they're working fine.


Agreed. They will be Schottky barrier types, which read way different from
'standard' silicon types. From the symptoms quoted, the most likely bet
would be a small electrolytic on the primary side gone high ESR, but also
could be many other things, including resistors gone high. Unless there is a
particular issue regarding size or physical shape, I wouldn't bother going
any further than you already have. These PSU's are so cheap now as genereric
replacements, they don't warrant the labour to fix them. It's also a good
opportunity to up its rating for the same money.

Arfa


  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 28
Default Testing two TO220 recifiers...

Meat Plow wrote:
On Sun, 10 Dec 2006 18:41:50 -0800, lj_robins Has Frothed:

Hi,

I'm trying to repair an ATX power supply that has been dying a slow
death, turning the power switch on the back off/on has allowed the
computer to boot up for a couple of months but the supply finally died.

Shorting the two power wires on the bulk connector that normally make
the supply come on just make the supply give a little "Ziiiiiit" noise
then a very faint high frequency squeal can be heard.

I pulled the heat sink with the three transistors (two transistors and a
MOSFET) all three tested fine. I then pulled the heat sink with the
three rectifiers, one tested in the normal range but the other two were
testing at 0.99x and 0.2xx, I would normally expect these to be in the
0.4xx or 0.5xx, sometimes a low 0.6xx, is this normal?

The two rectifiers in question a SB1040 and SB1640.

Any help would be appreciated.


-Landon


It will probably cost you nearly as much in time and effort to repair the
supply as it would to buy a new one. My guess is you have a dry
electrolytic somewhere but without the proper meter to test them it will
be trial and error to find. But hey if you have the time, who am I to
discourage you? It is very rewarding especially for a newbie to revive
things like this. Just be carefull though.


Hi,

Thanks to those that have so far replied.

I figured that those two Schottky rectifiers were fine the way they were
testing, the numbers just didn't make any sense.

If I were paying my own technician to diagnose this the supply would
have already been replaced and the computer would have been out the door
and back to the customer. But every ATX supply that has died in this
house acts exactly the same way (gives the ziiiiit and has low output
voltage) and I'm kind of curious as to what is dying on the circuit boards.

One supply that was iffy about whether or not it would stay on depended
on how much was hooked up to it, that ended up being a very obviously
bulged filter capacitor on the output side. I replaced it with one that
was double the voltage rating of the old capacitor, two years later that
supply is still running and ended up being a 60 cent (US) fix.

But, back to the point, I probably will just replace the supply.


Thanks again.

-Landon


  #6   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 1,572
Default Testing two TO220 recifiers...


Thanks to those that have so far replied.

I figured that those two Schottky rectifiers were fine the way they were
testing, the numbers just didn't make any sense.
If I were paying my own technician to diagnose this the supply would
have already been replaced and the computer would have been out the door
and back to the customer. But every ATX supply that has died in this
house acts exactly the same way (gives the ziiiiit and has low output
voltage) and I'm kind of curious as to what is dying on the circuit boards.





It's almost always electrolytic capacitors. They dry out internally and
the ESR goes way up, eventually the voltages sag and get noisy and then
when it gets bad enough, it won't power up at all.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
testing Jason D. Electronics Repair 2 June 30th 06 05:16 AM
Testing Wood Addict Woodworking 1 December 31st 05 04:42 AM
Laws requiring portable appliance testing and electrical installation testing if any? Z UK diy 9 June 14th 04 11:00 AM


All times are GMT +1. The time now is 01:42 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"