I´ve got a Technics Open Reel RS-1500US (1982 model).
Suddenly don't work anymore, any reason apparently. All function (FF, REW, Play, etc.) start O.K. but immediately stop, (aprox. 1 second later). I notice that the electro-brake is engaged (solenoid is defeat) one second after any function is selected, that means no movement is permitted, consequently the Open Reel turn off. The three motor are O.K., solenoids are O.K. This equipment never was repaired and no maintenance performed. I don't have wiring diagram. Can anyone suggest what might be wrong? Regards, Patrick. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Technics Open Reel RS-1500 US
Check your power supply carefully for bad solder joints and bad/weak capacitors. I worked on a similar unit that drove us nuts for weeks. Same basic symptoms, on play unit would start up, solenoids engaging, reels starting to turn - then solenoids dropping out and reels stopping almost instantly. Surge from solenoids actuating was spiking the power supply enough to upset the logic, which can be fairly convoluted. We finally realized it was a combination of bad cap and bad solder. The power supply was not straight forward either. Good luck tomh PGE wrote: I´ve got a Technics Open Reel RS-1500US (1982 model). Suddenly don't work anymore, any reason apparently. All function (FF, REW, Play, etc.) start O.K. but immediately stop, (aprox. 1 second later). I notice that the electro-brake is engaged (solenoid is defeat) one second after any function is selected, that means no movement is permitted, consequently the Open Reel turn off. The three motor are O.K., solenoids are O.K. This equipment never was repaired and no maintenance performed. I don't have wiring diagram. Can anyone suggest what might be wrong? Regards, Patrick. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Open Neutral indication on switched split wired receptacle circuit | Home Ownership | |||
auto hold open storm door closers | Home Repair | |||
Use BOTH hands to open new double glazed door? | UK diy | |||
Are open fireplaces considered desirable by the average house-buyer? | UK diy |