relay
Hi group --- I need a couple of relays for the control board in an air
conditioner. The unit is a Carrier and the coils on both relays are open. These relays are on two different boards and were replaced at two different times about a year apart. The number on the relay is Potter&Brumfield T9AV5D22-24 It has a 240volt coil. TIA John |
relay
Potter & Brumfield is a really major relay maker. I would start by going to
their web site, determining whether this is a current production product, and checking who sells it in small quantities. "john carson" wrote in message ... Hi group --- I need a couple of relays for the control board in an air conditioner. The unit is a Carrier and the coils on both relays are open. These relays are on two different boards and were replaced at two different times about a year apart. The number on the relay is Potter&Brumfield T9AV5D22-24 It has a 240volt coil. TIA John |
relay
In article ,
john carson wrote: Hi group --- I need a couple of relays for the control board in an air conditioner. The unit is a Carrier and the coils on both relays are open. These relays are on two different boards and were replaced at two different times about a year apart. The number on the relay is Potter&Brumfield T9AV5D22-24 It has a 240volt coil. TIA John Burnt out coils are pretty unusual. But two at once? -- *Procrastinate now Dave Plowman London SW To e-mail, change noise into sound. |
relay
"Dave Plowman (News)" wrote in message ... In article , john carson wrote: Hi group --- I need a couple of relays for the control board in an air conditioner. The unit is a Carrier and the coils on both relays are open. These relays are on two different boards and were replaced at two different times about a year apart. The number on the relay is Potter&Brumfield T9AV5D22-24 It has a 240volt coil. TIA John Burnt out coils are pretty unusual. But two at once? Lightning strike? |
relay
On Wed, 19 Jul 2006 18:10:29 GMT, john carson put
finger to keyboard and composed: Hi group --- I need a couple of relays for the control board in an air conditioner. The unit is a Carrier and the coils on both relays are open. These relays are on two different boards and were replaced at two different times about a year apart. The number on the relay is Potter&Brumfield T9AV5D22-24 It has a 240volt coil. TIA John AFAICS, the relay has a 24V DC coil and 30A contacts: http://catalog.tycoelectronics.com/T...AV5D22-24&I=13 - Franc Zabkar -- Please remove one 'i' from my address when replying by email. |
relay
In article ,
mc wrote: Burnt out coils are pretty unusual. But two at once? Lightning strike? Possibly, but I'd expect many other things to fail first. -- *When the chips are down, the buffalo is empty* Dave Plowman London SW To e-mail, change noise into sound. |