Hi,
I have an F36649yx51 that won't turn on.
When power button is pressed the deguass relay
clicks 5 to 7 times and that's all.

I checked the voltage at the collector of the HOT Q14401 and it was
normal @ 140v.
I connected a light bulb in series between the collector of
the HOT and the flyback - it lit up and the relay clicked twice
(normal) and the power light stayed on but no HV.
I've replaced the flyback transformer T14401 - no change
When I unplug the CRT driver board there is no change.
I plugged the CRT driver board back in and disconnected the filament
on pin 10 and the power light stays on.
I don't know what to do next.
Has anybody had any experience with this failure before?


Regards,
Siggy


  #2   Report Post  
Posted to sci.electronics.repair
 
Posts: n/a
Default RCA CTC203 - deguass relay clicks


Siggy wrote:
Hi,
I have an F36649yx51 that won't turn on.
When power button is pressed the deguass relay
clicks 5 to 7 times and that's all.

I checked the voltage at the collector of the HOT Q14401 and it was
normal @ 140v.
I connected a light bulb in series between the collector of
the HOT and the flyback - it lit up and the relay clicked twice
(normal) and the power light stayed on but no HV.
I've replaced the flyback transformer T14401 - no change
When I unplug the CRT driver board there is no change.
I plugged the CRT driver board back in and disconnected the filament
on pin 10 and the power light stays on.
I don't know what to do next.
Has anybody had any experience with this failure before?


Regards,
Siggy


What does the horizontal output drive waveform look like on the
o'scope?
Have you already removed, cleaned, and repaired the glue contaminated
connections to the coil on the base of the HOT?

  #3   Report Post  
Posted to sci.electronics.repair
Art
 
Posts: n/a
Default RCA CTC203 - deguass relay clicks

Had one the other day, the jungle chip was the culprit, no drive from it at
all.
wrote in message
oups.com...

Siggy wrote:
Hi,
I have an F36649yx51 that won't turn on.
When power button is pressed the deguass relay
clicks 5 to 7 times and that's all.

I checked the voltage at the collector of the HOT Q14401 and it was
normal @ 140v.
I connected a light bulb in series between the collector of
the HOT and the flyback - it lit up and the relay clicked twice
(normal) and the power light stayed on but no HV.
I've replaced the flyback transformer T14401 - no change
When I unplug the CRT driver board there is no change.
I plugged the CRT driver board back in and disconnected the filament
on pin 10 and the power light stays on.
I don't know what to do next.
Has anybody had any experience with this failure before?


Regards,
Siggy


What does the horizontal output drive waveform look like on the
o'scope?
Have you already removed, cleaned, and repaired the glue contaminated
connections to the coil on the base of the HOT?



  #4   Report Post  
Posted to sci.electronics.repair
Jason D.
 
Posts: n/a
Default RCA CTC203 - deguass relay clicks

On Fri, 02 Jun 2006 17:15:05 -0500, Siggy
wrote:


Hi,
I have an F36649yx51 that won't turn on.
When power button is pressed the deguass relay
clicks 5 to 7 times and that's all.

I checked the voltage at the collector of the HOT Q14401 and it was
normal @ 140v.
I connected a light bulb in series between the collector of
the HOT and the flyback - it lit up and the relay clicked twice
(normal) and the power light stayed on but no HV.
I've replaced the flyback transformer T14401 - no change
When I unplug the CRT driver board there is no change.
I plugged the CRT driver board back in and disconnected the filament
on pin 10 and the power light stays on.
I don't know what to do next.
Has anybody had any experience with this failure before?


Regards,
Siggy



If this model have PIP feature (easily identified by looking at the
stand up module with A/V inputs) have large IC in the metal shield.
With LM317 regulator for 3.3V on steel heatsink at one corner. Look
at adjust pin of this LM317 for 2 SMD resistors. Resolder this SMD
two resistors.

Cheers, Wizard
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
TV power problem, relay clicks, only turns on when you hit it [email protected] Electronics Repair 3 May 30th 06 11:51 PM
JVC TV model AV-27730 relay clicks repeatedly [email protected] Electronics Repair 0 September 8th 05 05:26 AM
CTC177BE Dead. Relay Clicks 3 Times Model F27630 MarkC Electronics Repair 18 August 28th 05 12:46 PM