Hi,
got a Tek 2215a to repair. At start, caps on +5V was dead, making a direct link between +5 and ground. now I can see lines or signals on crt but wit maximum intensity, which is not good. Z-Axis logic is ok, if I turn either A or B intensity channel I can see signal amplitude changing. So problem comes from DC restorer, but even with service manual, I can't see what's going wrong. At the DC restorer's output (control grid) I only have the DC component (which is -2 kv ??!!) and AC component from Z-Axis logic is not here anymore. So I thought somes diodes where out but I checked caps resistors and diodes all components seems to be ok. Also I checked connection between DC restorer and CRT wires are's ok too. What can be the problem ??? thanks and sorry for english level Laurent |