I'm getting out my old projects from the past couple of years to decide
on whether to finish them or pitch them. I found a Hitachi v-1065 scope that I'd like to get running. I'm not sure, but the flyback may be out on it. The hitachi number for the flyback is 8474287-b according to my service manual. There's a fuse (.6A) between 55v and the flyback that blew. When I jumper it, the voltage drops to 25v. Any ideas? The caps, I suspect, maybe have low ESR, so I'm changing them out. I've already ordered a new HOPT, just in case (I have a tendency to ruin those things even when they are still good). -josh |
#2
|
|||
|
|||
" wrote in
oups.com: I'm getting out my old projects from the past couple of years to decide on whether to finish them or pitch them. I found a Hitachi v-1065 scope that I'd like to get running. I'm not sure, but the flyback may be out on it. The hitachi number for the flyback is 8474287-b according to my service manual. There's a fuse (.6A) between 55v and the flyback that blew. When I jumper it, the voltage drops to 25v. Probably the flyback driver XSTR. Maybe associated diodes,too. Any ideas? The caps, I suspect, maybe have low ESR, *LOW* ESR is -desirable-. Caps are bad when their ESR -rises-. I suggest getting a Dick Smith ESR meter,they are GREAT,and low cost,well worth the money. so I'm changing them out. I've already ordered a new HOPT, just in case (I have a tendency to ruin those things even when they are still good). -josh -- Jim Yanik jyanik at kua.net |
#3
|
|||
|
|||
*LOW* ESR is -desirable-. Caps are bad when their ESR -rises-.
That's what I meant... Been a long time since I've worked on electronics! I suggest getting a Dick Smith ESR meter,they are GREAT,and low cost,well worth the money. Already on the list of "gotsta get." -josh |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Repair Hitachi 60inch projection TV (model 60SX1K) | Electronics Repair | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair | |||
ATT; Hobbyists and Repairmen I have accumulated a room of ICS, Transistors, Diodes , Mem Chips , Proms etc | Electronics Repair | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair |