View Single Post
  #23   Report Post  
Art
 
Posts: n/a
Default

Maybe even the pcc diode and associated cap?
"kip" wrote in message
.. .
Ok its a CTC169...
You will have to rebuild the SMPS section ...First 2.2mfd 22mfd 39mf
Then whilst in standby mode check voltages....+15Von cr4118
Then ...134V on HOT collector
If OK fine..
If not rebuild Horizontal Out section HOT/Blue Box caps etc..
Whilst in there replace HV Block..

kip
"fosjef67" wrote in
message .. .
The TV had been making an arc sound for quite some time when the set
was cold, however everything still worked fine. Which leads me to
believe that the HV splitter was having some issues? However now
while doing some test I fine that I don't even have power going to
the HV transformer. The only place I can seem to fine any juice in
the system is on main board to the right of the set (if looking in
from the rear). If anyone could make any suggestions I would
appreciate it. It is a classic case of worked one day and not the
next