Default fit LV lamp to mains halogen fitting?

RichardS noaccess@invalid wrote:
"Ian Stirling" wrote in message
...
Lurch wrote:
On 28 Jun 2004 07:21:37 GMT, Ian Stirling
strung together this:

Probably not a good idea.

Oh really.


Yes, really.

The current for a LV fitting will be some 20 times that of a mains one,
and the heating for a given contact resistance 400 times.

What significance would the current draw be then?


The contacts of the mains lamp may have been designed for a much, much
lower current (lower pressures, smaller contact area) than the LV ones.
If you exceed the designed current by a factor of 20, then the sockets
can just die.
Much as if you tried to pull 260A from a mains plug.


Yes, but the contacts are irrelevant here - they will have to be binned and
replaced with the standard LV connector (completely incompatible).


Oh well.
Sorry, I haven't dealt much with HV bulbs, and the one that I thought
I saw had an identical connector.