View Single Post
  #1   Report Post  
MarkC
 
Posts: n/a
Default CTC177BE Dead. Relay Clicks 3 Times Model F27630

Came in dead with no click. Replaced shorted HOUT but it blew instantly
at turn on. Then replaced fly & HOUT but then only got the relay
clicking 3 times. Came across a sym/cure about horizontal being out of
phase because of a corrupted eprom so I tried jumping C4402 with an
identical .015 cap and now the set does turn on with a good picture
(except of course for the bending pincushion effect because of the
jumped caps). I tried a new eprom but still have the same problem. So
the current status is that it powers up when C4402 is jumped but it
doesn't power up when not jumped and a new eprom didn't solve the
problem. Any suggestions are greatly appreciated. Thanks, Mark