greetings
you have to change the existing nipple in the tank
the cold side has the dip tube, so your hot just gets a brass nipple
and a 3/4 copper to female adapter.
unscrew the existing nipple. use about a 3inch brass nipple, with a
copper stub pre-sweated in the female adapter, so you keep the heat off
the tank
you should use teflon tape but also the grey pro dope , [ not the blue
crap that hardens up] smear a little grey dope in the female "hot"
opening of the tank. tape the nipple and also put some grey dope over
that.
the anode rod should be changed every 8 yrs. its screwed in the top of
the tank. some water should be drained off the bottom every couple of
months.
but 1 last thing....that tank being up in the attic, if its over 10 yrs
old....i would consider a new one, thats a disaster in the making.
--good luck
--
whodat
------------------------------------------------------------------------
whodat's Profile:
http://www.homeplot.com/member.php?userid=35
View this thread:
http://www.homeplot.com/showthread.php?t=57010