View Single Post
  #4   Report Post  
 
Posts: n/a
Default

Bart Bervoets wrote:
I found a capacitor burned/partially shorted in primary power supply.
Type is 471K 1KV, i want to replace with 471K 2KV, is that ok?
Cannot find other fault, HOT was fine after all, battery multimeter
flat caused faulty reading.
Can this be all?


That will be fine. Maybe also replace the switching FET, as a problem
with this capacitor could blow it up.

P.S. I think you indeed have a real Philips set, so it's worth the
repairs.

---
Met vriendelijke groet,

Maarten Bakker.