View Single Post
  #2   Report Post  
Roy and Rosa
 
Posts: n/a
Default

Fuse is F506 not 504
With Hot removed I get no 130 voltage. I replaced the str30130 but still no
130volt.
I have 156 vdc at pin 3.
pin2 has 133 vdc when turned on.
pin4 goes up above 100 vdc for an instant( my fluke is too slow to read
where it realy goes to) and quickly drops down to nothing.
thanks roy
"Roy and Rosa" wrote in message
...
magnavox RJ4324 20F1 chassis is dead.
Found shorted HOT and blown fuse 504 I think...1 amp
Flyback rings good.

I replaced fuse and HOT. Set powered up for just a fraction of a second.
Just long enough to shake dust off the HV lead. Blew fuse and HOT again.
Nothing obvious bad. Caps check OK for ESR.
I cant find any tips on the web for this chassis.
Where should I look? Anyone have a schematic or service manual?
Thanks to all.
Roy
Rbeaty -at- grandecom.net