View Single Post
  #4   Report Post  
Proctologically Violated©®
 
Posts: n/a
Default

What a pita--I think I'll just sweat some 45s for offsets!

Or, buy the equiv. diam in soft copper tube/coil!!! Dat's proly the best
way to go, iffin you don't care about laser-straight piping...
----------------------------
Mr. P.V.'d
formerly Droll Troll
"carl mciver" wrote in message
ink.net...
Anneal it first, then pack the tubing with sand and plug the ends.
Then
bend. The tubing will work harden as you bend it, so you might have to
bend
a little then heat some, then bend and repeat. The sand will keep it from
collapsing.

"Proctologically Violated©®" wrote in message
news | Awl--
|
| I bend EMT all the time, w/ an emt bender.
| Could I bend "gentle" offsets in rigid copper tubing (L, M)? 90's??
| Mebbe heat it first?
| ----------------------------
| Mr. P.V.'d
| formerly Droll Troll
|
|