"1" bravely wrote to "All" (07 Apr 05 10:21:04)
--- on the heady topic of " jvc hr-s9600"

1 From: "1" 1@1
1 Xref: aeinews sci.electronics.repair:45184

1 "Asimov" schreef in
1 bericht ...
"JVC Dude" bravely wrote to "All" (05 Apr 05 09:25:41)
--- on the heady topic of " jvc hr-s9600"

The simplest method to time these is to (with power plug pulled)
remove the basket, then turn the loading mechanism by hand until the
load arms would just stop retracting the tape. This is the STOP
position. Then align all the gears so that the basket can be mounted
in the down position. When the machine is then powered up it should
reset itself to the tape eject position. This method should work in
99% of all machines.

A*s*i*m*o*v


1 This would discribe the threading alligment?? Correct me if i am
1 wrong.

Herm, alignment is relative to each vcr model. Some are simpler to
reset the gears than others. Most have some sort of cam which controls
the tape loading arms but which also relates to the basket gears. What
often happens is the relationship between the tape load arms and
basket position is accidentally upset for various reasons, i.e. jammed
tape, forced loading or removal, broken parts, etc, resulting in
slipped of skipped gears.

A*s*i*m*o*v